(b)  
Open these circuit breakers and attach the DO-NOT-CLOSE tags:
 NOTE: Open these circuit breakers when you remove GCU 1.
____
 1)  On the P180 or P180-1 panel:
 a) C8 or M4, GCU 1
 b) B25, GCU 1 ALT
 2)  On the P514 panel:
 a) GCU 1 PHASE C SYNCH BUS
 (c) Open these circuit breakers and attach the DO-NOT-CLOSE tags:
 NOTE: Open these circuit breakers when you remove GCU 2.
____
 1)  On the P180 or P180-1 panel:
 a) C9 or M5, GCU 2
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-23-01
 ALL  ú ú 02 Page 403 ú Oct 10/95 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 b) B26, GCU 2 ALT 2) On the P614 panel: a) GCU 2 PHASE C SYNC BUS
 (d)  Open these circuit breakers and attach the DO-NOT-CLOSE tags:
 NOTE: Open these circuit breakers when you remove GCU 3.
____
 1)  On the P180 or P180-1 panel: a) C10 or M6, GCU 3 b) B27, GCU 3 ALT
 2)  On the P515 panel: a) GCU 3 PHASE C SYNC BUS
 (e)  Open these circuit breakers and attach the DO-NOT-CLOSE tags:
 NOTE: Open these circuit breakers when you remove GCU 4.
____
 1)  On the P180 or P180-1 panel: a) C11 or M7, GCU 4 b) B28, GCU 4 ALT
 2)  On the P615 panel: a) GCU 4 PHASE C SYNCH BUS
 D.  Remove the Control Unit
 S 864-016
 (1)  
Make sure the BATTERY switch, on the P5 panel, is set to OFF and attach a DO-NOT-OPERATE tag.
S 024-003
 (2)  
Remove the applicable GCU or BCU from the E/E rack (AMM 20-11-22/401).
 TASK 24-23-01-404-004
 3.  Generator and Bus Control Unit Installation (Fig. 401)
___________________________________________
 A.  References
 (1) AMM 20-11-22/401 Rack-Mounted Electrical/Electronic Module
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-23-01
 ALL  ú ú 02 Page 404 ú Oct 10/94 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 
MAINTENANCE MANUAL
 (2)  
AMM 24-22-00/201, Manual Control
 (3)  
AMM 45-10-00/201, Central Maintenance Computer System
 (4)  
AIPC 24-23-01, Fig. 20
 (5)  
AIPC 24-23-01, Fig. 30
 (6)  
WDM 24-11-11 thru WDM 24-11-14, WDM 24-21-12, WDM 24-21-22, WDM 24-21-32, WDM 24-21-42, WDM 24-22-11 thru WDM 24-22-74, WDM 24-23-11 thru WDM 24-23-22, WDM 24-27-51 thru WDM 24-27-52, WDM 24-41-12 thru WDM 24-41-23
 (7)  
SSM 24-11-01 thru SSM 24-11-04, SSM 24-21-01 thru SSM 24-21-04, SSM 24-22-01 thru SSM 24-22-07, SSM 24-23-01 thru SSM 24-23-02, SSM 24-23-04, SSM 24-27-01 thru SSM 24-27-07, SSM 24-32-02, SSM 24-34-01 thru SSM 24-34-03, SSM 24-41-01 thru SSM 24-41-02
 B. 
Access
 (1)  
Location Zone
 117 Electrical and Electronics Compartment, LH
 118 Electrical and Electronics Compartment, RH
 C. 
Install the Generator Control Unit or the Bus Control Unit
 S 424-005
 (1)  
Install the applicable GCU or BCU in the E/E rack
 (AMM 20-11-22/401).
 S 864-017
 (2)  
Remove the DO-NOT-OPERATE tag from the BATTERY switch.
 