(2)
AMM 24-22-00/201, Manual Control
(3)
WDM 24-22-11, WDM 24-22-12, WDM 24-22-13, WDM 24-22-14, WDM 24-22-31, WDM 24-22-32, WDM 24-22-41
(4)
SSM 24-22-01, SSM 24-22-03, SSM 24-22-04
B.
Access
(1)
Location Zone
222 Control Cabin, RH
C.
Procedure
S 864-002
(1)
Make sure all electrical power is off (AMM 24-22-00/201).
S 864-003
(2)
Make sure the BATTERY switch, on the P5 panel, is set to OFF and attach a DO-NOT-OPERATE tag.
S 034-004
(3)
Remove the module:
(a)
Turn the six panel fasteners that attach the module to the P461 panel counterclockwise 90 degrees.
(b)
Disconnect the electrical connectors from the module. (Refer to the table below for the equipment numbers).
~......................... | ELECTRICAL | MODULE | | CONNECTOR | RECEPTACLE | ........................... | DM7322A | J1 | | DM7322B | J2 | | DM7322C | J3 | | DM7322D | J4 | | DM7307E | J5 | | DM7307F | J6 | 2............…............1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-22-06
ALL ú ú 01 Page 401 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
PILOTS' OVERHEADSEE A
MAINTENANCE PANEL P461 GENERATOR FIELD MANUAL RESET MODULE (M7322)
A
Generator Field Manual Reset Module Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-22-06
ALL ú ú 01 Page 402 ú Jun 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(c)
Remove the module from the P461 panel.
(d)
Install caps on all electrical connectors.
TASK 24-22-06-404-008
3. Generator Field Manual Reset Module Installation (Fig. 401)________________________________________________
A. References
(1)
AIPC 24-22-51, Fig. 1
(2)
AMM 24-22-00/201, Manual Control
(3)
WDM 24-22-11, WDM 24-22-12, WDM 24-22-13, WDM 24-22-14, WDM 24-22-31, WDM 24-22-32, WDM 24-22-41
(4)
SSM 24-22-01, SSM 24-22-03, SSM 24-22-04
B.
Access
(1)
Location Zone
222 Control Cabin, RH
(2)
Access Panel
P461 Pilots' Overhead Maintenance Panel
C.
Procedure
S 424-015
(1)
Install the module:
(a)
Remove all caps from the electrical connectors.
(b)
Connect the six electrical connectors to the six receptacles on the module. (Refer to the table below for the equipment numbers.)
~......................... | ELECTRICAL | MODULE | | CONNECTOR | RECEPTACLE | ........................... | DM7322A | J1 | | DM7322B | J2 | | DM7322C | J3 | | DM7322D | J4 | | DM7307E | J5 | | DM7307F | J6 | 2............…............1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-22-06
ALL ú ú 01 Page 403 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(c)
Put the module in its position on the P461 panel.
(d)
Turn the six panel fasteners that attach the module to the P461 panel clockwise 90 degrees.
S 864-013
(2) Remove the DO-NOT-OPERATE tag from the BATTERY switch.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(2)