747-400 MAINTENANCE MANUAL
 b) UV protection is not set.
 c) US protection is not set.
 d) OC protection is not set.
 2)  If none of the protective trips are present and power is available for 150 |50 milliseconds, the AGCU signals the APB to close.
 (l)  Protective Trips
 1)  The AGCU also causes relays and breakers to trip in order to protect the EPGS under fault conditions. These relays and breakers are the AGCR and the APB.
 2)  AGCR protective trip occurs if one of the following is confirmed: a) OV protection is set. b) UV protection is set. c) Differential current fault protection is set. d) Fire switch is pressed.
 3)  APB protective trip occurs if there is an AGCR protective trip, OC protection is set, or if a US condition is confirmed.
 (9)  
Bus Control Unit (Fig. 6)
 (a)  
Each of the two BCUs are identical and interchangeable. A BCU provides functions to control and protect the synchronizing bus for coordinated system performance. The BCU analyzes incoming data from the electrical power generating system and performs the following control functions and protection.
 (b)  
The BCU provides the interface between the GEN FIELD switch and the adjacent AGCU for GCR control. The BCU will also send a GCR trip signal when an auxiliary generator bearing failure is detected continuously for 5 minutes.
 (c)  
The BCU provides the interface between the APU GEN switch and the adjacent AGCU for APB control. The BCU can also trip the APB directly. 1) The BCU will send a +28 volts dc APB close signal to the
 AGCU when the airplane is in ground mode and the following
 conditions are all true:
 a) APB is open.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-23-00
 ALL  ú ú 03 Page 17 ú Jun 10/89 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 
MAINTENANCE MANUAL
FUNCTION  SENSING  THRESHOLD  DELAY TIME  TRIPS  REMARKS  
EXT PWR OVER-VOLTAGE 1 (OV1)  HIGH PHASE VOLTAGE  INHIBITED BELOW 125 129 |4 VOLTS  INVERSE  GSTR, GHR XPC, GSSR,  LOCKOUT BELOW 125 VOLTS LINE-TO-NEUTRAL  
EXT PWR OVER-VOLTAGE 2 (OV2)  HIGH PHASE VOLTAGE  OV >140 VOLTS2  260 |10 MSEC  INTERNAL EXT PWR CONTACTOR  
VOLTAGE (UV) EXT PWR UNDER- 3 PHASE AVERAGE VOLTAGE  VOLTS LINE-T0-NEUTRAL 104.5 |1.5  9.0 |1.0 SEC  XPC, GSSR, GSTR, GHR  INSTANTANEOUS TRIP WHEN VOLTS <60V BACKUP DC BATTERIES <18V  
EXT PWR OVER-FREQUENCY (OF)  EXT PWR .C  OF 427.5 |2.5 Hz 1 OF 437.5 |2.5 Hz 2  1 0.8-1.6 SEC OF SEC 2 .20-.04 OF  XPC, GSSR, GSTR, GHR  
EXT PWR UNDER-FREQUENCY (UF)  EXT PWR .C  1 2 UF 372.5 |2.5 Hz UF 352.5 |2.5 Hz  0.8-1.6 SEC 1 2 UF 0.1-0.2 SEC UF  GSTR, GHR XPC, GSSR,  
EXT PWR PHASE  PHASE A-B-C  THE CLOSURES OF XPC, GSSR,  
SEQUENCE  AND GHR ARE INHIBITED WHEN THE PHASE SEQUENCE IS NOT A-B-C  
APU GENERATOR BEARING FAILURE  SWITCH/CONTACT  CONNECTION GROUND COMPLETED 5 MINUTES  AGCR IN AGCU  TO BOTH BCU'S THE INPUT IS FROM APU GEN  
NEGATIVE  PHASE A-B-C  18.5 |6.0 VOLTS  INVERSE  XPC, APB,  
SEQUENCE  OF SYNC BUS  SSB,  
VOLTAGE (NSV)  VOLTAGE  ADJACENT BTBs 
Bus Control Unit (BCU) Protective Functions 
Figure 6 (Sheet 1)