• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-09 10:26来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 TASK 24-33-02-004-001
 2.  DC Voltage Sense Relay Removal (Fig. 401)______________________________
 A.  References
 (1)
24-22-00/201, Manual Control

 (2)
IPC 24-33-01 Fig. 61

 (3)
WDM 24-33-12

 (4)
SSM 24-33-01

 B.  
Access

 (1)  
Location Zone
 222 Control Cabin, RH


 (2)  
Access Panel
 P6 Main Power Distibution Panel


 C.  
Procedure

 (1)
Make sure all electrical power is off (Ref 24-22-00/201).

 (2)
Open the access doors for the P6 panel.

 (3)
Disconnect the electrical connector (DR7228) from the relay.

 S 024-022

 (4)
Remove the relay:

 (a)
Remove the four screws that attach the relay to the P6 panel.


 S 864-002
 S 014-004
 S 034-005
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-33-02
 ALL  ú ú 01 Page 401 ú Oct 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

747-400 MAINTENANCE MANUAL
SEE A
SCREW (4 PLACES)
SEE B
P6 POWER DISTRIBUTION PANEL 

ELECTRICAL 
CONNECTOR  DC VOLTAGE SENSE 
RECEPTACLE  RELAY (R7228) 

B
DC Voltage Sense Relay Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-33-02
 ALL  ú ú 01 Page 402 ú Oct 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b) Remove the relay from the panel.
 TASK 24-33-02-404-008
 3.  DC Voltage Sense Relay Installation (Fig. 401)___________________________________
 A. References
 (1)
24-22-00/201, Manual Control

 (2)
IPC 24-33-01 Fig. 61

 (3)
WDM 24-33-12

 (4)
SSM 24-33-01

 B.
Access

 (1)  
Location Zone
 222 Control Cabin, RH


 (2)  
Access Panel
 P6 Main Power Distribution Panel


 C.
Install the DC Voltage Sense Relay


 S 424-023
 (1)
Install the relay:

 (a)
Put the relay in its position on the P6 panel.

 (b)
Install the four screws that attach the relay to the panel.

 (c)
Tighten the screws.


 S 434-011
 (2)
Connect the electrical connector (DR7228) to the relay.

 S 414-012

 (3)
Close the access doors for the P6 panel.

 D.
Do a Test of the DC Voltage Sense Relay

 (1)
Supply electrical power (Ref 24-22-00/201).

 S 714-024

 (2)
Do a test of the relay.

 (a)
Set the BATTERY switch, on the P5 panel, to OFF.


 S 864-025
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-33-02
 ALL  ú ú 01 Page 403 ú Oct 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b)
Open this circuit breaker:

 1)  P6 Main Power Distribution Panel
 a) 6A25 XFR RELAY STBY


 (c)
Make sure the main EICAS screen operates correctly.

 (d)
Open this circuit breaker:

 1)  P6 Main Power Distribution Panel
 a) 6A26 XFR RELAY BAT


 (e)
Make sure the main EICAS screen does not operate.

 (f)
Close this circuit breaker:


 1)  P6 Main Power Distribution Panel
 a) 6A25 XFR RELAY STBY
 b) 6A26 XFR RELAY BAT

 S 864-026
 (3) Remove electrical power, if it is not necessary (Ref 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(82)