(2)
WDM 24-32-31
(3)
SSM 24-32-03
B.
Access
(1)
Location Zone
271 Passenger Cabin, LH
C.
Procedure
S 864-002
(1)
Verify APU switch, located on the P5 overhead panel, is set to the OFF position and attach DO-NOT-OPERATE identifier.
S 864-003
(2)
Open circuit breakers as follows for APU TRU, and attach DO-NOT-CLOSE identifiers:
(a)
P180, DC Power Distribution Panel
1) 180C7, APU-TRU CONT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-32-04
ALL ú ú 02 Page 401 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
E-8 RACK (REF)
SEE A SEE B
E-33 EQUIPMENT RACK
A
SCREW
(4 PLACES)
WASHER
(4 PLACES)
NUT (4 PLACES)
APU TRANSFORMER RECTIFIER (H123)
ELECTRICAL
CONNECTOR
(DH123)
NOTE: DC TERMINAL LEADS NOT
B ____ SHOWN FOR CLARITY.
APU Transformer Rectifier Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-32-04
ALL ú ú 01 Page 402 ú Feb 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b) P183, E-33 Equipment Center Panel
1) APU TRU FAN CONT
2) APU TRU FAN SUPPLY
3) APU TRU START
S 034-005
(3)
Disconnect electrical connector (DH123) from receptacle on APU TRU.
S 034-006
(4)
Remove three nuts from the APU TRU fan shroud to gain access to the APU TRU power terminals. Remove fan shroud.
S 034-022
(5)
Remove two terminal nuts and two washers that secure each of the two APU TRU power leads to the APU TRU; disconnect leads.
NOTE: Identify each of the terminal leads that connect to the
____ terminals of the APU TRU for reinstallation.
S 434-028
(6)
Reinstall terminal nuts and washers. Tighten finger-tight.
S 434-026
(7)
Reinstall APU TRU fan shroud and secure with the three nuts. Tighten nuts.
S 034-007
(8)
Remove four bolts and washers securing APU TRU to the E-33 equipment rack.
S 024-021
(9)
Remove APU TRU from E-33 equipment rack.
TASK 24-32-04-404-022
3. Install APU Transformer Rectifier Unit (Fig. 401)
______________________________________
A. Special Tools and Equipment
(1)
T477W Bonding Meter
B.
References
(1)
AMM 25-59-05/601, Sidewall and Ceiling Insulation
(2)
AMM 49-11-00/201, Auxiliary Power Unit
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-32-04
ALL ú ú 04 Page 403 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL