(2)
IPC 24-51-02 Fig. 1
(3)
IPC 24-51-02 Fig. 2
(4)
IPC 24-51-02 Fig. 3
(5)
IPC 24-51-02 Fig. 4
(6)
WDM 24-51-11, 24-51-21, 24-51-31, 24-51-41
(7)
SSM 24-51-01, 24-51-02, 24-51-03, 24-51-04
B.
Access
(1)
Location Zone 117 Electrical and Electronics Compartment, LH 118 Electrical and Electronics Compartment, RH
(2)
Access Panel
P514 Generator 1 Power Center - Left
P614 Generator 2 Power Center - Left
P515 Generator 3 Power Center - Right
P615 Generator 4 Power Center - Right
C.
Procedure
(1)
Make sure all electrical power is off (Ref 24-22-00/201).
S 864-003
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-51-05
ALL ú ú 01 Page 401 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
SEE B UTILITY POWER 1 ELCU (M3250)
SEE C
P514
SEE A
P614
UTILITY POWER 2 ELCU
(M3251)
SEE C
P514 and P614 GENERATOR
1 and 2 POWER CENTER-LEFT
UTILITY POWER 3 ELCU A
(M3252)
SEE C
P515
P615
UTILITY POWER 4 ELCU (M3253)
SEE C
P515 and P615 GENERATOR 3 and 4 POWER CENTER-RIGHT
B
ELCU
(TYPICAL) C
Utility Power Electrical Load Control Unit Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-51-05
ALL ú ú 01 Page 402 ú Oct 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 024-004
(2) Open the applicable panel to get access to the ELCU.
~........................................ | Equipment Number | .......................................... | ELCU | Connector | Panel | .......................................... | M3250 | DM3250 | P514 | | M3251 | DM3251 | P614 | | M3252 | DM3252 | P515 | | M3253 | DM3253 | P615 | 2.............….............…............1
S 034-005
(3)
Disconnect the electrical connector from the ELCU.
S 034-023
(4)
Disconnect the electrical leads from the ELCU:
(a)
Remove the screws that attach the two terminal covers to the ELCU.
(b)
Remove the terminal covers.
(c)
Remove the nuts and the washers that attach the electrical leads to the terminal studs on the ELCU.
(d)
Attach an identification tag to each electrical lead.
(e)
Remove the electrical leads from the terminal studs.
S 024-022
(5)
Remove the ELCU:
(a)
Remove the four screws that attach the ELCU to the panel.
(b)
Remove the ELCU from the panel.
(c)
Install the terminal washers and the terminal nuts on the ELCU.
TASK 24-51-05-404-010
3. Utility Power Electrical Load Control Unit Installation (Fig. 401)_______________________________________________________
A. References
(1) 24-22-00/201, Manual Control
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(118)