EXTERNAL POWER RECEPTACLES (INSIDE VIEW) 
B 
AC External Power - Component Location 
Figure 102 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-41-00
 ALL  ú ú 01 Page 102 ú Dec 10/88 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
747-400 
FAULT ISOLATION/MAINT MANUAL
P714 AUX/EXT NO. 1 POWER CENTER 
SEE C 
EXTERNAL POWER CONTACTOR 1, R12 
P714 AUX/EXT NO. 1 POWER CENTER 
C 
P715 AUX/EXT 
NO. 2 POWER 
CENTER
SEE D 
EXTERNAL POWER 
TRANSFORMER 
RECTIFIER UNIT A, 
T97
EXTERNAL POWER 
TRANSFORMER 
RECTIFIER UNIT B, 
T1FWD 
EXTERNAL POWER TRANSFORMER 
RECTIFIER UNITS
E 
AC External Power - Component Location Figure 102 (Sheet 2) 
EXTERNAL POWER TRANSFORMER RECTIFIER UNITS 
SEE E 
EXTERNAL 
POWER 
CONTACTOR 2, 
R13 
P715 AUX/EXT NO. 2 POWER CENTER 
D 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-41-00
 ALL  ú ú 01 Page 103 ú Dec 10/88 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 AC EXTERNAL POWER - ADJUSTMENT/TEST
___________________________________
 1.  General_______
 A.  This section contains a task to do an operational test of the ac external power system. The operational test includes procedures for correct distribution and indication of the ac external power system.
 B.  For this operational test, you must connect the two external power receptacles to two different external power sources.
 TASK 24-41-00-715-001
 2.  Operational Test - AC External Power (Fig. 501 and 502)____________________________________
 A.  General
 (1)  
Most of the switches and lights you must use are on the P5 overhead panel. Other panels you must use are identified in the procedure.
 B.  
References
 (1)  
24-22-00/201, Manual Control
 (2)  
45-10-00/201, Central Maintenance Computer System
 (3)  
WDM 24-41-12 thru 24-41-31
 (4)  
SSM 24-41-01 thru 24-41-03
 C.  
Access
 (1)  
Location Zone 118 Electrical and Electronics Compartment, RH 221 Control Cabin, LH
 (2)  
Access Panel
 118A Electrical Power Receptacle Door
 D.  
Prepare for the Test
 (1)  
Apply external power to the airplane (Ref 24-22-00/201).
S 715-011
 (2)  
Test the indicator lights for the electrical system.
 (a)  
Set the IND LTS switch, on the P5 overhead panel, to TEST.
 S 865-002
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-41-00
 ALL  ú ú 03 Page 501 ú Oct 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
747-400 MAINTENANCE MANUAL 
SEE A 
SEE B
ELECTRICAL SYSTEM CONTROL MODULE  
A  
POWER NOT IN  
USE LIGHTS  AC CONNECTED  
LIGHT  EXTERNAL POWER  
AC CONNECTED  RECEPTACLE DOOR  
LIGHT 
EXTERNAL POWER EXTERNAL POWER FWD 
RECEPTACLE 
RECEPTACLE 
NO. 1 (D51) NO. 2 (D52)
EXTERNAL POWER RECEPTACLES 
B 
Electrical System Control Module/External Power Receptacle Location 
Figure 501
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-41-00
 ALL  ú ú 01 Page 502 ú Jun 10/89 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(89)