(a)
P6, Main Power Distribution Panel
1) 6F1, IGN 1 ENG 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-29-00
ALL ú ú 05 Page 510 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) 6K19, IGN 2 ENG 1
3) 6G19, STBY IGN ENG 1
4) 6F2, IGN 1 ENG 2
5) 6K20, IGN 2 ENG 2
6) 6G20, STBY IGN ENG 2
7) 6F3, IGN 1 ENG 3
8) 6K21, IGN 2 ENG 3
9) 6G21, STBY IGN ENG 3
10) 6F4, IGN 1 ENG 4
11) 6K22, IGN 2 ENG 4
12) 6G22, STBY IGN ENG 4
S 085-123
(2) Remove electrical power, if it is not necessary (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-29-00
ALL ú ú 04 Page 511 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
MAIN STATIC INVERTER - REMOVAL/INSTALLATION
___________________________________________
1. General_______
A. This procedure has two tasks. One task is the removal of the main static inverter (M7438). The other task is the installation of the main static inverter.
B. The installation task includes an operational test of the main static inverter.
C. The main static inverter is installed in the E-30 equipment rack. The main static inverter is adjacent to the main battery charger and the four main TRUs. The E-30 equipment rack is between the nose gear wheel well and the fuselage, on the right side. Access to the E-30 equipment rack is through an access opening forward of the E/E compartment.
TASK 24-29-01-004-001
2. Main Static Inverter Removal (Fig. 401)____________________________
A. References
(1)
20-11-22/401, Rack-Mounted Electrical/Electronic Module
(2)
IPC 24-29-01 Fig. 1
(3)
WDM 24-33-13
(4)
SSM 24-33-02
B.
Access
(1)
Location Zone 116 Area Between Nose Gear Well and Fuselage, RH
C.
Procedure
S 864-002
(1)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a)
P6 Main Power Distribution Panel
1) 6K2 MN BAT CONT INVERTER PWR
2) 6K5 TRU - CONT INVERTER PWR
(2)
Make sure the standby power switch is set to OFF.
S 024-003
(3)
Remove the main static inverter from the E-30 equipment rack (Ref 20-11-22/401).
S 944-015
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-29-01
ALL ú ú 03 Page 401 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SEE B
SEE A
E-30 EQUIPMENT RACK
A
STATIC INVERTER (M7438)
B
Static Inverter Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-29-01
ALL ú ú 01 Page 402 ú Jun 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
TASK 24-29-01-404-004
3. Main Static Inverter Installation (Fig. 401)_________________________________
A. References
(1)
20-11-22/401 Rack-Mounted Electrical/Electronic Module
(2)
24-22-00/201, Manual Control
(3)
45-10-00/201, Central Maintenance Computer System
(4)
IPC 24-29-01 Fig. 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(32)