S 865-029
 (13)
 Open this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6A26, XFR RELAY BAT
 S 215-118
 (14)
 Examine the EICAS screens.
 (a)  
Make sure that data shows on the lower EICAS screen.
 (b)  
Make sure that data does not show on the upper EICAS screen.
 S 865-042
 (15)
 Close this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6A25, XFR RELAY STBY
 S 715-043
 (16)
 Make sure that data shows on the upper and lower EICAS screens.
S 865-032
 (17)
 Close this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6A26, XFR RELAY BAT
 (18)
 Make sure that data shows on the upper and lower EICAS screens.
S 865-035
 (19)
 Open these circuit breakers:
 (a)  
P6, Main Power Distribution Panel
 1) 6A5, TRU 1
 2) 6A14, TRU 2
 S 715-034
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-29-00
 ALL  ú ú 05 Page 508 ú Feb 18/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 3) 6A32, TRU 4
 4) 6A25, XFR RELAY STBY
 S 715-075
 (20)
 Examine the EICAS screens.
 (a)  
Make sure that data shows on the lower EICAS screen.
 (b)  
Make sure that data does not show on the upper EICAS screen.
 S 865-039
 (21)
 Close this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6J7, MN BAT RELAY CONT
 S 715-040
 (22)
 Make sure that data shows on the upper and lower EICAS screens.
S 865-036
 (23)
 Close these circuit breakers:
 (a)  
6A5, TRU 1
 (b)  
6A14, TRU 2
 (c)  
6A32, TRU 4
 (d)  
6A25, XFR RELAY STBY
 E. 
Do the Operational Test of the APU Static Inverter
 S 865-157
 (1)  
Open this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6J5, APU INV XFR RLY PWR CONT
 S 715-045
 (2)  
Make sure that data shows on the captain's primary flight display (PFD) and navigation display (ND) screens.
S 865-052
 (3)  
Open this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6A8, APU STBY XFR RELAY
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-29-00
 ALL  ú ú 06 Page 509 ú Feb 18/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 S 715-053
 (4)  
Make sure that data does not show on the captain's PFD or ND screens.
S 865-054
 (5)  
Close this circuit breaker:
 (a)  
P6, Main Power Distribution Panel
 1) 6J5, APU INV XFR RLY PWR CONT
 S 715-055
 (6)  
Make sure that data shows on the captain's PFD and ND screens.
S 865-144
 (7)  
Set the STANDBY POWER switch to BAT.
S 715-057
 (8)  
Make sure that data shows on the captain's PFD and ND screens.
S 865-058
 (9)  
Set the STANDBY POWER switch to AUTO.
S 865-151
 (10)
 Close this circuit breaker:
 (a)  
P6 Main Power Distribution Panel
 1) 6A8, APU STBY XFR RELAY
 S 715-060
 (11) Make sure that data shows on the upper and lower EICAS screens.
 F. Put the Airplane to its Usual Condition
 S 865-178
 (1)  
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(31)