R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. 08-048 D DA-2-657-4
ADHESIVE (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-42-00-861-001 Energize the Ground Service Network from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
__________
Subtask 30-72-11-860-050
A. Aircraft Maintenance Configuration
(1)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
(2)
Make sure that the access platform is set in position at the potable-water panel 171AL.
(3)
Make sure that the panel is openend and the darin control handle is set to the NORM position.
(4)
Make sure that the access platform is set in position at the AFT cargo compartment door.
(5)
Make sure that the AFT cargo compartment door is openend (Ref. TASK 52-30-00-860-001).
(6)
Make sure that the partition 161DW is removed to get access to the thermostat and the terminal block 7510VT.
R **ON A/C 001-049, 052-099, 101-105, 201-210,
Subtask 30-72-11-865-051
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SERVICE PANEL HEATER 15DV E08
**ON A/C 051-051,
Subtask 30-72-11-865-051-B
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU ICE PROT - SERVICE PANEL HTR 15DV E08
R **ON A/C 106-149, 151-199, 211-299, 301-399, 401-499,
Subtask 30-72-11-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU HEATER SERV PANEL 15DV D01
**ON A/C ALL
4. Procedure
_________
Subtask 30-72-11-420-050
A. Installation of the Thermostat
(1)
Do an inspection of the component interface and/or the adjacent area.
(2)
Put the thermostat-housing (6) on the stud (5).
(3)
Put the threaded-sleeve (7) in position.
(4)
Tighten the threaded-sleeve (7) with a torque wrench to 0.05 m.daN
(4.42 lbf.in).
NOTE : A threaded overlap is not required.
____
(5) Secure the threaded-sleeve (7) with BONDING AND ADHESIVE COMPOUNDS (Material No. 08-048).
(6) Install the thermostat-housing cover (3) with the srews (4), the washers (2) and the nuts (1).
(7) Connect the electrical connections (8) with the insertion-removal tool M15.570-20 to the terminal block 7510VT.
中国航空网 www.aero.cn