R 1EFF : 001-049, 051-099, 101-149, 152-199, 1 30-45-00Page 308 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
30-45-00-040-002 Deactivation of the Rain Repellent System
3. Job Set-up__________
Subtask 30-45-00-865-063
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R R **ON A/C 001-049, 051-052, 054-056, 058-059, 061-099, 101-101, 103-149, 152-199, 201-299, 301-399, 401-499, Post SB 30-1037 For A/C 001-049,051-052,054-056,
49VU ANTI ICE/RAIN/RPLNT/CAPT 1DB1 D01
R **ON A/C 001-049, 051-099, 101-149, 152-199, 201-299, 301-399, 401-499,
121VU COM NAV/RADAR/1 5SQ1 K13
**ON A/C 051-099,
121VU COM NAV/RADAR/2 5SQ2 K14
R **ON A/C 001-049, 051-099, 101-149, 152-199, 201-299, 301-399, 401-499,
122VU ANTI ICE/WINDOWS/R 122VU ANTI ICE/WHC/2 122VU ANTI ICE/F/O/WIPER 122VU ANTI ICE/WINDOWS/L 122VU ANTI ICE/WHC/1 122VU ANTI ICE/WIPER/CAPT 4DG2 5DG2 4DB2 4DG1 5DG1 4DB1 W14W13W12X14X13X12
R 1EFF : 001-049, 051-099, 101-149, 152-199, 1 30-45-00Page 309 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-052, 054-056, 058-059, 061-099, 101-101, 103-149, R 152-199, 201-299, 301-399, 401-499, Post SB 30-1037 For A/C 001-049,051-052,054-056,
122VU ANTI ICE/RAIN/RPLNT/F/O 1DB2 W11
R **ON A/C 001-049, 051-099, 101-149, 152-199, 201-299, 301-399, 401-499,
123VU ANTI ICE/L/WHSLD 1DG1 AF10 123VU ANTI ICE/R/WHSLD 1DG2 AF03
Subtask 30-45-00-941-064
B. Get Access
(1) On the panels 21VU and 22VU, put a warning notice to tell persons not to operate the CAPT and F/O RAIN RPLNT pushbutton switches.
Subtask 30-45-00-040-050
C. Deactivation of the Rain Repellent System
(1) Do the deactivation of the rain repellent system (Ref. TASK 30-45-00-040-002).
Subtask 30-45-00-941-066
D. Get Access to the Windshield
(1) Put an access platform in position below the windshield.
4. Procedure
_________
Subtask 30-45-00-100-050
A. Servicing of the Windshield Hydrophobic Coating
(1) Do the procedure given in the Master Kit P/N DSS 1040 - PPG Industries Document P/N DSS 1042 to do these maintenance tasks:
(a)
Windshield cleaning.
(b)
Check of the coating performance.
R 1EFF : 001-049, 051-099, 101-149, 152-199, 1 30-45-00Page 310 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
(c) Removal and application of the coating.
NOTE : A 220 VAC power source is necessary.
____
5. Close-up
________ Subtask 30-45-00-865-064
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1DG1, 1DG2, 4DG1, 4DG2, 5DG1, 5DG2, 4DB1, 4DB2, 5SQ1, 5SQ2
NOTE : Do not close the circuit breaker(s) related to the rain repellent
____ system. Do not remove the tag(s) related to the deactivation of the rain repellent system.
Subtask 30-45-00-410-056
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.