 (8) Install the electrical wires with the cable ties on the bracket.
 Subtask 30-72-11-861-051
 B. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). 
R  **ON A/C 001-049, 052-099, 101-105, 201-210,
 Subtask 30-72-11-865-052
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SERVICE PANEL HEATER 15DV E08 
R  **ON A/C 051-051, 
R  Subtask 30-72-11-865-052-B 
R R  C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 
R R R R  -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU ICE PROT - SERVICE PANEL HTR 15DV E08

 


R **ON A/C 106-149, 151-199, 211-299, 301-399, 401-499,

 Subtask 30-72-11-865-052-A
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU HEATER SERV PANEL 15DV D01
 **ON A/C 001-049, 051-099, 101-149, 201-299,
 Subtask 30-72-11-710-050
 D. Do this test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the potable water  At the potable water service-panel: service-panel:
 -apply cooling spray on and  - examine that the fill/drain nipple around the housing of the 11DV becomes warm. thermostat 12DV.

 

R  **ON A/C 151-199, 301-399, 401-499,
 Subtask 30-72-11-710-050-A
 D. Do this test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the potable water  At the potable water service-panel: service-panel:
 -apply cooling spray on and  - examine that the fill/drain nipple around the housing of the 11DV (13DV) becomes warm. thermostat 12DV (14DV).
 **ON A/C ALL
 5. Close-up
________
 Subtask 30-72-11-410-050

 A. Put the aircraft back to its initial configuration.
 (1)
 Install the partition 161DW.

 (2)
 Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).

 (3)
 Make sure that the drain control handle is in the NORM position and close the potable-water service panel 171AL.


 (4) Remove the access platform(s).
 Subtask 30-72-11-862-050

 B. De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).

 

 NIPPLE - FILL/DRAIN/OVERFLOW (11DV,13DV) - REMOVAL/INSTALLATION
_______________________________________________________________
 TASK 30-72-52-000-001
 Removal of the Heated Fill/Drain Nipple 11DV and/or Overflow Nipple 13DV
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 No specific insertion-removal tool M15.570-20
 No specific non-metallic scraper
 No specific access platform 1.5 m (4 ft. 11 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-24-38-680-002 Draining of the Potable Water System (without Electrical Power) 24-42-00-861-001 Energize the Ground Service Network from the External
 Power 30-72-11-000-001 Removal of the Thermostat 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump
 **ON A/C 001-049, 051-099, 101-149, 201-299,
 30-72-52-991-001 Fig. 401
R **ON A/C 151-199, 301-399, 401-499,
 30-72-52-991-001-A Fig. 401A **ON A/C ALL


 3. Job Set-up
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ICE AND RAIN PROTECTION 防冰和排雨2(100)