3. Job Set-up
__________
Subtask 30-71-00-861-053
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
Subtask 30-71-00-865-070
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU ICE PROT CARGO DRAIN VALVE 20DU D04 2001VU ICE PROT CARGO DRAIN VALVE 32DU D08
Subtask 30-71-00-010-051
C. Get Access
(1)
FOR 6DU, 56DU
-Open the FWD and AFT cargo-compartment door (Ref. TASK 52-30-00-860-001).
-Set the CARGO COMPT LIGHT switches to ON.
(2)
FOR 6DU
-Remove the FWD cargo-compartment floor panels 131TF, 132TF, (Ref. TASK 53-22-14-000-001).
(3)
FOR 56DU Remove the AFT cargo-compartment floor panels 151AG, 152AG, (Ref. TASK 53-42-14-000-001).
1EFF : 051-051, 1 30-71-00Page 517 1 1 Aug 01/05R 1 1 1CES 1
4. Procedure
_________
Subtask 30-71-00-720-050
A. Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At FR33 (FR58), on the FWD (AFT) At the FWD (AFT) air stop drain-valve: air stop drain-valve:
-Loosen the insulation and apply - The heating disk 6DU (56DU) becomes cooling spray on the thermostat warm. 7DU (57DU) for at least 10 seconds.
5. Close-up
________
Subtask 30-71-00-410-052
A. Close Access
(1)
FOR 6DU
-Install the FWD cargo-compartment floor panels 131TF, 132TF, (Ref. TASK 53-22-14-400-001).
(2)
FOR 56DU
-Install the AFT cargo-compartment floor panels 151AG, 152AG, (Ref. TASK 53-42-14-400-001).
(3)
FOR 6DU, 56DU
-Set the CARGO COMPT LIGHT switches to OFF.
-Close the FWD and AFT cargo-compartment door (Ref. TASK 52-30-00-860-002).
Subtask 30-71-00-862-054
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
R SENSOR - TEMPERATURE (40DU,50DU) - REMOVAL/INSTALLATION
_______________________________________________________
TASK 30-71-17-000-001
Removal of the Waste-Water De-icing Sensor (40DU)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific access platform 2 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------