-------------------------------------------------------------------------------2000VU WASTE WIP DRAINMAST FWD 1DU D01 2001VU WASTE WIP DRAINMAST AFT 11DU E01
R 1EFF : 052-099, 106-149, 151-199, 211-299, 1 30-71-00Page 409 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 401-499,
R Subtask 30-71-00-865-051-B
R R R R A. To activate the electrical supply remove the safety clip(s), tag(s) and close: - the C/B 1DU only for the FWD system, - the C/B 11DU only for the AFT system;
R R R R R -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU WASTE WATER ICE PROT - DRAINMAST FWD 1DU B06 2001VU WASTE WATER ICE PROT - DRAINMAST AFT 11DU E01
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 30-71-00-440-050
B. Reactivation (Ref. Fig. 401/TASK 30-71-00-991-001)
(1) Do the trouble-shooting of the waste-water drainmast heating-system: (Ref. TSM TASK 30-71-00-810-801) FWD Drainmast-Heater Failure and/or (Ref. TSM TASK 30-71-00-810-802) AFT Drainmast-Heater Failure and/or (Ref. TSM TASK 30-71-00-810-803) CTL Unit Failure of FWD Drainmast and/or (Ref. TSM TASK 30-71-00-810-804) CTL Unit Failure of AFT Drainmast
(2) Do the subsequent procedure to reactivate the related lavatory(ies): - remove the placard from the lavatory, - unlock and open the lavatory door, - open the shutoff valve of the lavatory washbassin.
(3) Do the subsequent procedure to reactivate the related galley(s): - remove the placard, - open the lavatory shutoff valve.
(4) Make a record of the reactivation(s) in the aircraft technical logbook.
R 1EFF : 001-049, 052-099, 101-149, 151-199, 1 30-71-00Page 410 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
**ON A/C 051-051,
Subtask 30-71-00-440-050-A
B. Reactivation
(Ref. Fig. 401/TASK 30-71-00-991-001)
(1)
Do the trouble-shooting of the waste-water drainmast heating-system: (Ref. TSM TASK 30-71-00-810-801) FWD Drainmast-Heater Failure and/or (Ref. TSM TASK 30-71-00-810-809) MID Drainmast-Heater Failure and/or (Ref. TSM TASK 30-71-00-810-802) AFT Drainmast-Heater Failure and/or (Ref. TSM TASK 30-71-00-810-803) CTL Unit Failure of FWD Drainmast and/or (Ref. TSM TASK 30-71-00-810-810) CTL Unit Failure of MID Drainmast and/or (Ref. TSM TASK 30-71-00-810-804) CTL Unit Failure of AFT Drainmast
(2)
Do the subsequent procedure to reactivate the related lavatory(ies):
-remove the placard from the lavatory,
-unlock and open the lavatory door,
- open the shutoff valve of the lavatory washbassin.
(3)
Do the subsequent procedure to reactivate the related galley(s):
-remove the placard,
- open the lavatory shutoff valve.
(4)
Make a record of the reactivation(s) in the aircraft technical logbook.
WASTE WATER ICE PROTECTION - ADJUSTMENT/TEST____________________________________________
TASK 30-71-00-710-001
Operational Test of the Drainmast Ice Protection
WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------