• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-24 08:57来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  Subtask 30-71-00-865-050-B 
R R R R  B. To deactivate the electrical supply open, safety and tag: - the C/B 1DU only for the FWD system, - the C/B 11DU only for the AFT system; 
R R R R R R R  -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------FOR 4DU 2000VU WASTE WATER ICE PROT - DRAINMAST FWD 1DU B06 FOR 14DU 2001VU WASTE WATER ICE PROT - DRAINMAST AFT 11DU E01 

R 1EFF : 151-199, 401-499, 1 30-71-00Page 404 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 4. Procedure
_________ Subtask 30-71-00-040-050
 A. Deactivation Procedure
 (Ref. Fig. 401/TASK 30-71-00-991-001)

 (1)
 Close the manual shutoff valve of the related lavatory water supply. The shutoff valve is installed at floor level next to and at the rear of the lavatory and you can clearly see the 'OPEN' and 'SHUT' positions.

 (2)
 Put a placard on the related lavatory doors to show persons that the lavatory is not in use.

 (3)
 Close and lock the lavatory doors.

 (4)
 Close the shutoff valve of the related galley water supply.

 (5)
 Put a placard on the related galley water supply to show persons that the water faucet does not operate.


 1EFF : ALL 1 30-71-00Page 405 1 1 Aug 01/05R 1 1 1CES 1


 Potable Water Lavatory Shut of Valve Figure 401/TASK 30-71-00-991-001
 1EFF : 1 1R 1CES  ALL  1 11 1 30-71-00 Page 406 Aug 01/05

 

 TASK 30-71-00-440-001
 Reactivation of the Waste-Water Drain Mast Heating-System
 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 30-71-01
 Drain Mast Ice Protection -Waste Water Drain Mast Heating System

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
 External Power TSM 30-71-00-810-801 FWD Drainmast-Heater Failure TSM 30-71-00-810-802 AFT Drainmast-Heater Failure TSM 30-71-00-810-803 Control Unit Failure of FWD Drainmast TSM 30-71-00-810-804 Control Unit Failure of AFT Drainmast TSM 30-71-00-810-809 MID Drainmast-Heater Failure TSM 30-71-00-810-810 Control Unit Failure of MID Drainmast 30-71-00-991-001 Fig. 401
 3. Job Set-up
__________
 Subtask 30-71-00-861-050
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
 WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED
_______ BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
 1EFF : ALL 1 30-71-00Page 407 1 1 Aug 01/05R 1 1 1CES 1

 4. Procedure
_________

 **ON A/C 001-049, 101-105, 201-210, 301-399,
 Subtask 30-71-00-865-051
 A. To activate the electrical supply remove the safety clip(s), tag(s) and close:
 -
the C/B 1DU only for the FWD system,

 -
the C/B 11DU only for the AFT system;


 -------------------------------------------------------------------------------
PANEL ------ SERVICE --------------------------------------------------- IDENT. ------------- LOCATION---------
2000VU WASTE WIP DRAINMAST FWD  1DU  B06
 2001VU WASTE WIP DRAINMAST AFT  11DU  E01
 **ON A/C 051-051,
 Subtask 30-71-00-865-051-E
 A. To activate the electrical supply
 remove the safety clip(s), tag(s) and close:
 - the C/B 1DU only for the FWD system,
 - the C/B 21DU only for the MID system,
 - the C/B 11DU only for the AFT system;
 ------PANEL  ---------------------------------------------------SERVICE  -------------IDENT.  ---------LOCATION

 -------------------------------------------------------------------------------2000VU ICE PROT - DRAINMAST FWD 1DU D02 2001VU ICE PROT - DRAINMAST MID 21DU D07 2001VU ICE PROT - DRAINMAST AFT 11DU D06
R 1EFF : ALL 1 30-71-00Page 408 1 1 Aug 01/05 1 1 1CES 1

 **ON A/C 052-099,


 Subtask 30-71-00-865-051-A
 A. To activate the electrical supply remove the safety clip(s), tag(s) and close
 -
the C/B 1DU only for the FWD system,

 -
the C/B 11DU only for the AFT system;


 -------------------------------------------------------------------------------
PANEL ------ SERVICE --------------------------------------------------- IDENT. ------------- LOCATION---------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ICE AND RAIN PROTECTION 防冰和排雨2(54)