ACTION RESULT -------------------------------------------------------------------------------
1. On the control unit 3DW: On the control unit 3DW:
-Push and hold the TEST - The green LEDs I/II and (III/IV) come pushbutton switch. on.
-Release the TEST pushbutton - The green LEDs I/II and III/IV go switch. off.
**ON A/C ALL
5. Close-up
________ Subtask 30-73-00-410-052
A. Close Access
(1)
Make sure that the work area is clean and clear of tools and other items.
(2)
FOR 3DW
-Install the sidewall panel 132JW.
-Close the FWD cargo-compartment door (Ref. TASK 52-30-00-860-001). Subtask 30-73-00-862-051
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 30-73-00Page 505 1 1 Aug 01/05R 1 1 1CES 1
TASK 30-73-00-720-001
Functional Test of the Potable Water Ice-Protection
WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______
YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS
_______
ONLY WITH A GOOD SUPPLY OF AIR.
OBEY THE MANUFACTURERS INSTRUCTIONS.
PUT ON PROTECTIVE CLOTHING.
DO NOT GET THEM IN YOUR MOUTH.
DO NOT SMOKE.
DO NOT BREATHE THE GAS.
THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific cooling spray
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power FOR FIN 10DW, 4DW, 5DW, 6DW, 9DW 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump R FOR FIN 10DW, 16DW, 4DW, 9DW
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R R R R R R R R R R R R R 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump FOR FIN 16DW, 333DW, 334DW, 335DW, 4DW 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump FOR FIN 333DW, 334DW, 335DW 25-54-12-000-001 Removal of the FWD Cargo Compartment Partition FR34 25-54-12-400-001 Installation of the FWD Cargo Compartment Partition FR34 FOR FIN 10DW, 16DW, 300DW, 311DW, 321DW, 322DW, 323DW, 331DW, 332DW, 333DW, 334DW, 4DW 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump FOR FIN 332DW, 333DW, 334DW 25-54-12-000-001 Removal of the FWD Cargo Compartment Partition FR34 25-54-12-400-001 Installation of the FWD Cargo Compartment Partition FR34
3. Job Set-up__________
Subtask 30-73-00-861-052
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
R **ON A/C 001-049, 051-099, 101-105,
Subtask 30-73-00-865-054
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ICE AND RAIN PROTECTION 防冰和排雨2(107)