Set the CARGO COMPT light switch 8LU to ON.
-Remove the sidewall panel 162CW.
**ON A/C ALL
4. Procedure
_________ R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 401-499,
(Ref. Fig. 401/TASK 30-71-34-991-001)
**ON A/C 051-051,
(Ref. Fig. 401A/TASK 30-71-34-991-001-B)
**ON A/C 301-399,
(Ref. Fig. 401B/TASK 30-71-34-991-001-A)
**ON A/C ALL
Subtask 30-71-34-020-051
A. Removal of a control unit (Typical)
(1)
Disconnect the electrical connector (6).
(2)
Put blanking caps on the disconnected electrical connectors.
Control Unit 5DU/15DU
Figure 401/TASK 30-71-34-991-001
R 1EFF : 001-049, 052-099, 101-149, 151-199, 1 30-71-34Page 408 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
R Control Unit 25DU
R Figure 401A/TASK 30-71-34-991-001-B
R 1EFF : 051-051, 1 30-71-34 Page 409
1 1 May 01/05
1 1
1CES 1
Control Unit 5DU/15DU/140DU
R Figure 401B/TASK 30-71-34-991-001-A
R 1EFF : 301-399, 1 30-71-34 Page 410
1 1 May 01/05
1 1
1CES 1
(3)
Remove the screws (5), the washers (4) and the brackets (3) which hold the control unit (2) in position.
(4)
Remove the control unit (2) from its support (1).
R 1EFF : ALL 1 30-71-34Page 411 1 1 May 01/05 1 1 1CES 1 TASK 30-71-34-400-001
Installation of the Waste-Water Ice-Protection Control-Unit
NOTE : The procedure is the same for all the control units.
____
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 30-71-00-710-001 Operational Test of the Drainmast Ice Protection
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 401-499,
30-71-34-991-001 Fig. 401
**ON A/C 051-051,
30-71-34-991-001-B Fig. 401A
**ON A/C 301-399,
30-71-34-991-001-A Fig. 401B FOR FIN 5DU 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump FOR FIN 15DU 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
FOR FIN 15DU, 25DU
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
FOR FIN 3DW, 5DU
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
FOR FIN 3DW
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
FOR FIN 140DU, 5DU
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
FOR FIN 140DU
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
**ON A/C ALL
3. Job Set-up
__________
R **ON A/C 001-049, 052-099, 101-149, 211-299, 401-499,
Subtask 30-71-34-860-050
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
R (2) FOR 5DU
(a)
Make sure that the FWD cargo-compartment door is open (Ref. TASK 52-30-00-860-001).
(b)
Make sure that the CARGO COMPT light switch 6LU is set to ON.
(c)
Make sure that the sidewall panel 131MW is removed.