 -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL | ZONE | ACCESS | ATA | | | | DOOR | REF.
 -------------------------------------------------------------------------------4DU DRAIN MAST-FWD 133 825 30-71-51 5DU CONTROL UNIT 131 825 30-71-34
 14DU DRAIN MAST-AFT 172 826 30-71-51
 15DU CONTROL UNIT 162 826 30-71-34 140DU CONTROL UNIT 132 825 141DU SENSOR 131 825 142DU TAPE-HEATER 127 825 146DU TAPE-HEATER 127 825 147DU TAPE-HEATER 127 825
 **ON A/C ALL
 3. System Description
__________________

R **ON A/C 001-049, 052-099, 101-105, 401-499,
 A. The waste water is discarded through the drain lines to the fwd heated drain mast 4DU and the rear heated drain mast 14DU to atmosphere, which are installed on the lower fuselage shell. The waste water is moved to the drain masts through gravity on the ground and differential pressure in flight.
 B. Each drain mast assembly has:
 -an aluminum alloy housing (aerodynamic shape),
 -a drain tube with integrated electrical heating-elements,
 -
an PTC temperature sensor (measures the ambient temperature),

 -
an over temperature switch (prevents damage to heating element),


 -A flange for installation of the drain mast is part of the top of the fairing. Two ice protection control units 5DU and 15DU control the 115 V AC 400Hz single phase to the related heater of the drain masts. The drain mast heating element operates from -55 deg C (-65 deg F) to +75 deg C (+160 deg F). The overtemperature switch installed in the drain mast will stop the power supply if the temperature increases above +120 deg C (+250 deg F).


 Waste Water Ice Protection - Component Location R Figure 005
R 1EFF : 301-399, 1 30-71-00Page 13 1 1 May 01/05 1 1 1CES 1


 C. Each heater has:
 -a self limiting element,
 -two power supply conections,
 -an inner insulation,
 -a copper shield (ground bonding connection),
 -an outer protection sheath.
 D. Each sensor has:
 -
a ceramic and epoxit housing,

 -
a sensing chip (contains a thermister),


 -two connection pins, The value of the thermister depends on the set temperature of the waste water lines.
 **ON A/C 051-051,
 A. The waste water is discarded through the drain lines to the fwd heated drain mast 4DU and the rear heated drain mast 14DU to atmosphere, which are installed on the lower fuselage shell. The waste water is moved to the drain masts through gravity on the ground and differential pressure in flight. Each drain mast assembly has:
 -an aluminum alloy housing (aerodynamic shape),
 -a drain tube with integrated electrical heating-elements,
 -
an PTC temperature sensor (measures the ambient temperature),

 -
an over temperature switch (prevents damage to heating element),


 -A flange for installation of the drain mast is part of the top of the fairing. Two ice protection control units 5DU and 15DU regulate the 115 V AC 400Hz single phase to the related heater of the drain masts. The drain mast heating element operates from -55 deg C (-65 deg F) to +75 deg C (+160 deg F). The overtemperature switch installed in the drain mast will stop the power supply if the temperature increases above +120 deg C (+250 deg F).
 B. The ice protection control unit 3DW and related a sensor control the drain line heaters to the drain masts, keeping the temperature of the drain tube between +6 deg C (+43 deg F) to +10 deg C (+50 deg F). The waste water drain lines are installed on supports and tightened with clamps and covered with insulation. The drainage system with drain funnels, pipes, a drain mast and an air stop drain-valve is installed in the FWD and AFT cargo compartments. It is used to drain condensation which can be present in the cargo compartment and can cause corrosion and the formation of ice.
R 1EFF : 001-049, 051-099, 101-105, 401-499, 1 30-71-00Page 14 1 1 Aug 01/05 1 1 1CES 1 115 V AC 400Hz direct from the fwd and aft C/B panels supply power to the air stop valves. The fwd and aft air stop drain valves have a heater and a thermostat installed in the valve, the thermostat controls the operation of the heater.


 C. Each heater has:
 -a self limiting element,
 -two power supply conections,
 -an inner insulation,
 -a copper shield (ground bonding connection),
 -an outer protection sheath.
 D. Each sensor has:
 -
a ceramic and epoxit housing,

 -
a sensing chip (contains a thermister),


 -two connection pins, The value of the thermister depends on the set temperature of the waste water lines.
 