• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:07来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 


 F.  Procedure (Fig. 301)
 S 843-006
 (1) Do these steps to remove the hydraulic fluid from the accumulator:
 (a)  
Look at the pressure indication of the HYD BRAKE PRESS gage on the Captain's Main Instrument Panel, P1.

 (b)  
Slowly push one set of brake pedals to the limit of travel, hold momentarily, and then release. Repeat this cycle 10 times. 1) Make sure the pressure indication of the HYD BRAKE PRESS


 gage decreases during manual brake operation.
 2)  After the 10 cycles of manual brake operation, make sure the HYD BRAKE PRESS gage shows no more decrease in pressure.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-09
 ALL  ú ú 01 Page 302 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

HYDRAULIC BRAKE ACCUMULATOR CHARGING EQUIPMENT INSTALLATION  HYDRAULIC BRAKE ACCUMULATOR 
SEE  A  MARKER CHARGING INSTRUCTIONS 
SEE  C 
GAGE PRESSURE READING DIRECT  BSEE MANIFOLD ASSEMBLY 
CHARGING EQUIPMENT INSTALLATION HYDRAULIC BRAKE ACCUMULATOR

CAP  CHARGING INSTRUCTIONS-HYDRAULIC ACCUMULATOR. 
MANIFOLD  900 WITH SYSTEM DEPRESSURIZED, CHARGE WITH DRY NITROGEN TO APPLICABLE PRESSURE PER CHART BELOW |50 PSI 

800
700
PRESSURE-PSI GAGE

GAS CHARGING
VALVE 600 500 .0
MANIFOLD

-50 -25 +25 +50 +75
ASSEMBLY  AMBIENT TEMP- `CENTIGRADE 
B  CHARGING INSTRUCTIONS MARKER 

Figure 301 Hydraulic Brake Accumulator Servicing 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-09
 ALL  ú ú 01 Page 303 ú Feb 10/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 213-009
 (2) Do these steps to do a check of the accumulator charge pressure:
 (a)  
Look at the charging instructions marker adjacent to the accmulator.

 (b)  
With a value for the ambient temperature of the airplane, find the correct charge pressure for the accumulator.

 (c)  
Look at the pressure indication on the direct reading pressure gage adjacent to the mainfold assembly.

 (d)  
Compare the indication of the direct reading pressure gage with the correct charge pressure shown on the charging instructions marker.


 S 613-025
 (3)  If necessary, service the Hydraulic Brake Accumulator.
 TASK 12-15-09-603-026
 3. Service the Hydraulic Brake Accumulator
_______________________________________
 A. General
 (1)  
This task contains a procedure to increase the precharge pressure of the Hydraulic Brake Accumulator.

 (2)  
In subsequent steps, the hydraulic brake accumulator is referred to as the accumulator.


 B. Consumable Materials
 (1)  
G01158 Nitrogen

 (2)  
If nitrogen is not available,
 Source of Clean Dry Air, maximum moisture
 content corresponding to an atmospheric dew
 point of -20 degrees F (-29 degrees C)

 

 C. References
 (1)  
AMM 09-11-00/201, Towing

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
AMM 29-11-00/201, Main Hydraulic Supply System

 (4)  
AMM 32-00-30/201, Landing Gear Door Locks


 D. Access
 (1)  Location Zone
 138 Body Landing Gear Well - Right

 E. Procedure
 S 613-010
 (1)  If necessary, do these steps to increase the charge pressure of the accumulator:
 (a)  
Remove the cap from the stem of the gas charging valve.

 (b)  
Attach a source of nitrogen or dry air to the stem of the gas charging valve.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 SERVICING 1(93)