 WARNING:_______OPEN THE SHUTOFF VALVE ON THE OXYGEN CYLINDER SLOWLY. IF THE GAS FLOWS TOO QUICKLY, HIGH TEMPERATURES CAN OCCUR IN THE SYSTEM. THIS CAN CAUSE INJURIES TO PERSONNEL AND DAMAGE TO THE AIRPLANE.

 (7)  
Open the shutoff valves in the oxygen system slowly. Use your hand (a maximum of approximately 25 inch-pounds, 2.82 newton-meters) to open them to the fully open position.


 TASK 12-15-08-603-154
 2. Supernumerary Oxygen System Servicing (Cylinder Replacement)________________________________________________________(Fig. 301)
 A. General
 (1)  
Read and obey the safety precautions and general instructions before you do the maintenance (AMM 35-00-00/201).

 (2)  
Use these procedures to remove and install an oxygen cylinder in the forward cargo sidewall, or ceiling locations. Do the procedures again for each oxygen cylinder that you replace.

 (3)  
You can use composite and steel cylinders at the same time in the same cylinder support structure.


 B. Standard Tools and Equipment
 (1)  
Caps and Plugs - Oxygen Clean, Protective

 (2)  
Cylinders - Oxygen, Fully Serviced


 C. Consumable Materials
 (1)  
G00091 Compound - Oxygen System Leak Detection (MIL-L-25567)

 (2)  
G01505 Copper Lockwire - 0.020 inch diameter

 (3)  
G00713 Cloth - Clean, Dry, Lint-Free, White, Cotton


 D. References
 (1)  AMM 20-41-01/201, Static Grounding (Airplanes)
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-08
 ALL  ú ú 13 Page 302 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
CARGO SIDEWALL
OXYGEN CYLINDER
(EXAMPLE)

SEE A
OXYGEN CYLINDER (EXAMPLE)
BAND STRAP CLAMP
NUT (ADJUSTED IN THE FACTORY)
SPRING
A 747-400 MAINTENANCE MANUAL 
OVERBOARD DISCHARGE LINE  VALVE SHUTOFF  HIGH PRESSURE CYLINDER COUPLING 
PRESSURE GAGE  COUPLING ASSEMBLY 


OUTBD 

CARGO SIDEWALL OXYGEN
TOGGLE LEVER
CYLINDER (EXAMPLE)
(CLOSED POSITION)
A
T-BOLT HOLDER
B
B
T-BOLT
A-A
SAFETY PIN
TOGGLE LEVER
B-B
Oxygen Cylinder Installation
Figure 301

M13273
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-08
 ALL  ú ú 04 Page 303 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
AMM 35-21-00/501, Supernumerary Oxygen System

 (4)  
IPC 35-20-00

 (5)  
IPC 35-21-00


 E.  Access
 (1)  Location Zones 122 Forward Cargo Container Compartment, Forward Half Right 124 Forward Cargo Container Compartment, Aft Half Right
 F.  Cargo Sidewall-Mounted Oxygen Cylinder Removal
 S 843-220
 (1)  Prepare to remove the oxygen cylinder:
 (a)  
Make sure that the airplane is correctly grounded (AMM 20-41-01/201).

 (b)  
Open this circuit breaker and attach a DO-NOT-REMOVE tag:

 1)  P7 Overhead Circuit Breaker Panel a) 7D4 OXYGEN VALVE & IND

 (c)  
Open the access panel to the oxygen cylinders.


 NOTE: The access panels are attached by snaps and velcro tape.
____
 S 023-219
 (2)  Remove the oxygen cylinder:
 CAUTION: DO NOT TIGHTEN THE SHUTOFF VALVE ON THE OXYGEN CYLINDER TO
_______ MORE THAN 25 INCH-POUNDS (2.8 NEWTON-METERS). THIS CAN CAUSE DAMAGE TO THE SHUTOFF VALVE.
 (a)  
Close the shutoff valve on all oxygen cylinders slowly.

 (b)  
Remove the tubing clamps as necessary.


 WARNING: LOOSEN THE COUPLING NUT SLOWLY TO RELEASE THE GAS SLOWLY.
_______ HIGH GAS PRESSURE CAN CAUSE THE CONNECTION TO COME APART WITH AN EXPLOSIVE FORCE. THIS CAN CAUSE INJURIES TO PERSONNEL AND DAMAGE TO THE AIRPLANE AND EQUIPMENT.
 