• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:07来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (d)  
Set the parking brake.

 (e)  
Pressurize hydraulic system 4 to 3000 psi (AMM 29-11-00/201).

 (f)  
Remove the pressure from hydraulic system 1 (AMM 29-11-00/201).

 (g)  
Let the pressure in hydraulic system 1, which shows on the EICAS, decrease to 1000 psi.

 


 NOTE: You can operate the flight controls to release the
____
 pressure faster.

 (h)  
Release the parking brake.

 (i)  
Repeat steps (b) through (h) until the HYD QTY on the EICAS display shows .80 to 1.10 or the reservoir fill gauge is in the green band.


 NOTE: Approximately 68 cubic inches, 0.3 US Gallons should
____ be transfered each time the sequence is repeated.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-12-01
 ALL  ú ú 01 Page 311 ú Oct 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 213-136
 (15)
 Make sure the OF, RF, or LO indication does not show on the EICAS maintenance page adjacent to the HYD QTY (1, 2, 3, 4).

 S 213-101

 (16)
 Make sure the system 1 quantity, which shows on the EICAS, does not drop below 0.80, and the system 4 quantity, which shows on the EICAS, does not go above 1.10.

 S 863-102

 (17)
 Remove the hydraulic power if it is not necessary (AMM 29-11-00/201).

 S 863-103

 (18)
 Remove the electrical power if it is not necessary (AMM 24-22-00/201).

 S 983-096

 (19)
 Procedure 4 (Transfer fluid from system 4 to system 1).


 (a)  Release the parking brake.
 (b)  Pressurize hydraulic system 4 to 3000 psi (AMM 29-11-00/201).
 (c)  Set the parking brake.
 (d)  Pressurize hydraulic system 1 to 3000 psi (AMM 29-11-00/201).
 (e)  Remove the pressure from hydraulic system 4 (AMM 29-11-00/201).
 (f)  Let the pressure in hydraulic system 4, which shows on the
 EICAS, decrease to 1000 psi.
 NOTE:____ You can operate the flight controls to release the
 pressure faster.
 (g)  Release the parking brake.
 (h)  Repeat steps (b) through (g) until the HYD QTY on the EICAS
 display shows .80 to 1.10 or the reservoir fill gauge is in the
 green band.
 NOTE:____ Approximately 68 cubic inches, 0.3 US Gallons should
 be transfered each time the sequence is repeated.

 S 213-139
 (20)
 Make sure the OF, RF, or LO indication does not show on the EICAS maintenance page adjacent to the HYD QTY (1, 2, 3, 4).

 S 213-097

 (21)
 Make sure the system 4 quantity, which shows on the EICAS, does not drop below 0.80, and the system 1 quantity, which shows on the EICAS, does not go above 1.10.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-12-01
 ALL  ú ú 01 Page 312 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 863-098
 (22)
 Remove the hydraulic power if it is not necessary (AMM 29-11-00/201).

 S 863-099

 (23)
 Remove the electrical power if it is not necessary (AMM 24-22-00/201).

 S 983-092

 (24)
 Procedure 5 (Transfer fluid from system 2 to system 4).


 (a)  Release the parking brake.
 (b)  Remove the pressure from hydraulic systems 1 and 4
 (AMM 29-11-00/201).
 (c)  Pressurize hydraulic system 2 to 3000 psi (AMM 29-11-00/201).
 (d)  Set the parking brake.
 (e)  Pressurize hydraulic system 4 to 3000 psi (AMM 29-11-00/201).
 (f)  Remove the pressure from hydraulic system 2 (AMM 29-11-00/201).
 (g)  Let the pressure in hydraulic system 2, which shows on the
 EICAS, decrease to 1000 psi.
 NOTE:____ You can operate the flight controls to release the
 pressure faster.
 (h)  Release the parking brake.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 SERVICING 1(40)