F. Drain and Flush the Toilet Tank
S 863-001
(1)
Supply electrical power (AMM 24-22-00/201).
S 863-002
(2)
Open the door to the service panel.
S 863-003
(3)
Open the outer cap on the drain valve assembly.
S 863-004
(4)
Connect the waste drain hose on the service cart to the drain valve assembly at the service panel.
(5)
Push the PUSH-TO-OPEN lever on the drain valve assembly.
(6)
Pull the handle for the toilet drain valve at the service panel.
(7)
Make sure the indicator light comes on.
S 683-032
(8)
Make sure that the toilet tank drains:
S 863-005
S 863-006
S 213-007
(a) Listen for the liquid flow through the hose that drains the toilet tank.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
12-17-61
ALL ú ú 03 Page 304 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b) Put your hand on the hose that drains the toilet tank, and feel the vibration of the liquid while it flows.
S 863-009
(9)
After you drain the toilet tank, push the handle for the toilet drain valve to the closed position.
S 863-033
(10)
Make sure the toilet drain valve indicator light is off.
S 613-010
(11)
Flush the toilet tank.
(a)
Connect the flush line on the service cart to the rinse fitting on the service panel.
(b)
Put a minimum of 7 U.S. gallons of water into the toilet tank with a pump.
(c)
If the rinse line shutoff valve will not open and it cannot be repaired immediately; Do the steps in "Manual Operation of the Rinse Line Shutoff Valve".
(d)
Pull the handle for the toilet drain valve at the service panel.
(e)
Make sure the indicator light comes on.
(f)
Make sure the toilet tank drains: 1) Listen for the liquid flow through the hose that drains the toilet tank.
2) Put your hand on the hose that drains the toilet tank to feel the vibration of the liquid while it flows.
(g)
Disconnect the line used to flush the toilet tank.
(12)
Push the handle for the toilet drain valve fully in.
(13)
Make sure the toilet drain valve indicator light is off.
S 023-050
(14)
Disconnect the drain hose for the toilet tank from the drain valve assembly.
S 863-011
S 213-012
G. Add Chemical Precharge to the Toilet Tank
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
12-17-61
ALL ú ú 03 Page 305 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 613-049
WARNING:_______ MAKE SURE YOU FOLLOW THE MANUFACTURER'S INSTRUCTIONS WHEN YOU
USE THE CHEMICAL PRECHARGE. THE CHEMICAL PRECHARGE CONTAINS
CORROSIVE AND/OR POISONOUS MATERIALS. THESE MATERIALS CAUSE
INJURY TO PERSONS OR DAMAGE TO THE AIRPLANE IF YOU DO NOT
FOLLOW THE INSTRUCTIONS.
CAUTION:_______ DO NOT ADD THE CHEMICAL PRECHARGE TO THE TOILET TANK IF THE
AIRPLANE WILL BE KEPT WHERE IT IS VERY COLD. THE CHEMICAL
PRECHARGE CAN FREEZE AND CAUSE DAMAGE TO THE TOILET WASTE
SYSTEM.
(1) Method I Procedure (Alternative to Method II) - Add the chemical precharge to the toilet tank through the toilet service panel.
(a)
Connect the chemical precharge hose from the service cart to the rinse fitting on the service panel.
(b)
Pump 4.5 U.S. gallons of the chemical precharge into the toilet tank.
(c)
Disconnect the chemical precharge hose.
S 613-051
WARNING: MAKE SURE YOU FOLLOW THE MANUFACTURER'S INSTRUCTIONS WHEN YOU
_______ USE THE CHEMICAL PRECHARGE. THE CHEMICAL PRECHARGE CONTAINS CORROSIVE AND/OR POISONOUS MATERIALS. THESE MATERIALS CAUSE INJURY TO PERSONS OR DAMAGE TO THE AIRPLANE IF YOU DO NOT FOLLOW THE INSTRUCTIONS.