• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 14:39来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (2)
 Apply SPECIAL MATERIALS (Material No. 05-005) around all screwheads.


 (3)
 Seal the bonding connections (Ref. TASK 20-28-00-912-004). Subtask 49-16-43-410-051

 B.
 Close Access

 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Set the LIGHT control switch to the OFF position.

 (3)
 Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001)

 (4)
 Remove the access platform(s).

 (5)
 Pressurize the reservoirs of the Hydraulic systems (Ref. TASK 29-14-00-614-002).

 (6)
 De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002)


 (7)
 Remove the warning notice.

 

 

 

 

 NOSE - AIR INTAKE - REMOVAL/INSTALLATION
________________________________________

R **ON A/C 001-003, 051-099, 401-499,
 TASK 49-16-44-000-001
 Removal of the Air Intake Nose (GTCP 36-300)

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
 External Power
 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs
 52-41-00-010-001 Open the APU Doors for Access
 49-16-44-991-001 Fig. 401

 3. Job Set-up
__________
 Subtask 49-16-44-860-053

 A. Aircraft Maintenance Configuration
 (1)
 Energize the ground service network
 (Ref. TASK 24-41-00-861-002).


 (2)
 On the panel 25VU, put the APU Master Switch to the ON position.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-14-00-614-001).

 

 

 Subtask 49-16-44-865-050
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 Subtask 49-16-44-010-050
 C. Get Access
 (1)
 Put the access platform in position below the APU compartment.

 (2)
 Open the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).


 4. Procedure
_________ (Ref. Fig. 401/TASK 49-16-44-991-001) Subtask 49-16-44-020-050
 A. Removal of the Air Intake Nose
 (1)
 Remove the screws (7 and 8), the washers (6 and 9), the end-profile

 (5) and the bracket (4).

 (2)
 Remove the screws (1).

 (3)
 Remove the bolts (10), the washers (11) and the nuts (12).

 (4)
 Remove the screws (3) and the washers (2).

 (5)
 Remove the air intake nose (13) from the air inlet duct (14).

 


 Air Intake Nose
 Figure 401/TASK 49-16-44-991-001

 CES  TASK 49-16-44-400-001


 Installation of the Air Intake Nose (GTCP 36-300)
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific wooden or plastic scraper
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER3(21)