(3)
Seal the bonding connections (Ref. TASK 20-28-00-912-004). Subtask 49-16-43-410-052
B.
Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
If the service panel was removed put it in position on the service frame and lock the 22 stud fasteners.
(3)
Close the maintenance door 314AR.
(4)
Make sure that the work area is clean and clear of tool(s) and other items.
(5)
Set the LIGHT SW 11LJ to the OFF position.
(6)
Close the APU access doors 315AL and 316AR.
(7)
Remove the access platform(s).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-43Page 411 201-210, Config-2 Aug 01/05
CES Subtask 49-16-43-860-054
C. Aircraft Maintenance Configuration.
(1)
Pressurize the reservoirs of the hydraulic systems.
(Ref. TASK 29-00-00-864-001).
(2)
De-energize the ground service network
(Ref. TASK 24-42-00-862-001)
(3)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4)
Remove the warning notice(s).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-43Page 412 201-210, Config-2 Aug 01/05
CES
FLAP - AIR INTAKE - REMOVAL/INSTALLATION
________________________________________ TASK 49-16-43-000-002 Removal of the Air Intake Flap (APS 3200)
1.
Reason for the Job
__________________
Self explanatory.
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 49-16-43-991-003 Fig. 401
3. Job Set-up
__________ Subtask 49-16-43-860-056
A. Aircraft Maintenance Configuration
(1)
Put a warning notice on the panel 25VU to tell persons not to start the APU.
(2)
Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
(3)
De-pressurize the hydraulic systems (Ref. TASK 29-00-00-864-001).
Subtask 49-16-43-865-053
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
4. Procedure
_________
(Ref. Fig. 401/TASK 49-16-43-991-003) Subtask 49-16-43-020-052
A. Removal of the Air Intake Flap
(1) Remove the actuator spindle (1) from the air intake flap (8). NOTE : Get access through the APU air intake in the fire wall at
____
FR80.
(a)
Remove and discard the cotter pin (3).
(b)
Remove the castle nut (4), the washer (5) the bolt (6) and disconnect the actuator spindle (1) from the air intake flap (8).
(2) Hold the air intake flap (8), remove the screws (7) and then the air intake flap (8) from the air inlet duct (2).
Air Intake Flap
Figure 401/TASK 49-16-43-991-003
CES TASK 49-16-43-400-002
Installation of the Air Intake Flap (APS 3200)
1. Reason for the Job
__________________
Self explanatory.
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
No specific Torque Wrench : range 0.00 to 1.20 m.daN