• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:21来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 WARNING : ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
_______
 -
ON THE TOILET WASTE SYSTEM, OR


 -
ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
 WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND
 WATER.
 THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).

 

 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
Packing 38-31-04 32 -070
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-16-38-613-001 Servicing of the Toilet System 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power 38-31-00-680-001 Draining of the Toilet System 38-31-00-790-002 Leak Test of the Vacuum Toilet System 38-31-74-400-001 Installation of the Waste Tank Drain Line 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump
 1EFF : ALL 1 38-31-71Page 408 1 1 May 01/05R 1 1 1CES 1


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------

R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 38-31-71-991-001 Fig. 401
 **ON A/C 051-051,
 38-31-71-991-001-A Fig. 401A
 **ON A/C ALL
 3. Job Set-up
__________
 Subtask 38-31-71-860-050
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the aircraft electrical ciruits are energized (Ref. TASK 24-41-00-861-002).

 (2)
 Make sure that the toilet system is drained (Ref. TASK 38-31-00-680-001).


 **ON A/C 001-049, 051-099, 101-105,
 Subtask 38-31-71-865-060
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
 tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08 **ON A/C 106-149, 151-199, 201-299,


 Subtask 38-31-71-865-060-A
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
 tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
 **ON A/C 301-399,
 Subtask 38-31-71-865-060-B
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
 tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
 **ON A/C ALL
 4. Procedure
_________
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 401/TASK 38-31-71-991-001)


R  **ON A/C 051-051, 
R  (Ref. Fig. 401A/TASK 38-31-71-991-001-A) 
R  **ON A/C ALL
 Subtask 38-31-71-420-050
 A. Installation of the Waste Drain Valve 3340MM
 (1) Remove the blanking plugs from the line ends.
 (2) Install a new Packing (4).
 (3) Put the waste drain valve 3340 MM (9) in position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(99)