 (a) If you do not hear a click from the limit switch (5): 1 Open the waste service panel-door (1).
_
 2 Turn the stud (2) counterclockwise half of a turn.

_
 3 Close the waste service panel-door (1).

_
 4 Do the procedure again until you hear a click from the limit

_
 switch (5).

 

R R  Waste Service Panel-Door Limit-Switch (44MG) Figure 202/TASK 38-31-00-991-009-A
 1EFF : 1 1 1CES  ALL  1 111 38-31-00 Page 207 Nov 01/98

 

 (b) If you hear a click from the limit switch (5): 1 Open the waste service panel-door (1).
_
 2 Turn the stud (2) clockwise half of a turn.

_
 3 Push the waste service panel-door (1) to the closed position.

_
 4 Do the procedure again until you do not hear a click from the

_
 limit switch (5).

 5 Turn the stud (2) counterclockwise half of a turn.
_
R (6) Turn the stud (2) counterclockwise approximately 2 mm (0.079 in.) R more.
 (7)
 Hold the stud (2), and tighten the nut (3).

 (8)
 Operate the toilets and make sure they flush correctly (Ref. TASK 38-31-00-710-009).


 5. Close-up
________
 Subtask 38-31-00-410-068

 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the waste service-panel door 172AR.

 (3)
 Remove the ground support and maintenance equipment, the special and standard tools and all other items.


 (4) Remove the access platform(s).
 Subtask 38-31-00-862-064

 B. De-energize the ground service network
 (Ref. TASK 24-41-00-862-002).

 

R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 TASK 38-31-00-820-003
 Adjustment of the Altitude Pressure Switch (43MG)
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 4M (13 FT)
 No specific 1 TEST UNIT - STATIC PITOT
 98D38308234001 1 ADAPTER - ALTITUDE PRESSURE SWITCH

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
 the External Power 32-69-00-860-001 Simulation of Flight, with the Aircraft on the Ground 38-31-00-710-002 Operational Test of the Vacuum Toilet System
 3. Job Set-up
__________
 Subtask 38-31-00-861-067

 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 38-31-00Page 209 1201-299, 1May 01/05 1 1 1CES 1 Subtask 38-31-00-010-080


 B. Get Access
 (1) Put the ACCESS PLATFORM 4M (13 FT) in position.
 (2) Open the access door 312AR.
 Subtask 38-31-00-860-057

 C. Preparation for Adjustment
 (1)
 Remove the electrical connector from the altitude pressure switch 43MG.

 (2)
 Install the ADAPTER - ALTITUDE PRESSURE SWITCH on the altitude pressure switch 43MG.

 (3)
 Connect the TEST UNIT - STATIC PITOT to the altitude pressure switch-adapter.


 4. Procedure
_________ R **ON A/C 001-049, 051-051, 056-056, 058-099, 101-105, 151-199, 201-299,
 Subtask 38-31-00-710-063
 A. Do this Test
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
 On the pitot tester:

- set the altitude to 4877 +213 -213 m (16000.94 +698.83 -698.83 ft.).

2.
 On the pitot tester:


-decrease the altitude to 3658 m (12001.53 ft.).
At the altitude pressure switch 43MG:
-do a check for continuity between thepins A and B.
-the pins A and B should monitor switch contact close.
At the altitude pressure switch 43MG:
-do a check for continuity between thepins A and C.
 -the pins A and C should monitor switch contact close.
 