(7)
Connect the electrical connectors (4, 6, 7 and 8).
Subtask 38-31-12-710-050
B. Operate the toilet and make sure that it flushes corrcetly (Ref. TASK 38-31-00-710-009).
5. Close-up
________ Subtask 38-31-12-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the toilet shroud (Ref. TASK 25-45-22-400-001).
(3) Close the lavatory door. Subtask 38-31-12-862-050
B. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
LIMIT SWITCH - WASTE PANEL DOOR (44MG) - REMOVAL/INSTALLATION
_____________________________________________________________
TASK 38-31-13-000-001
Removal of the Waste Service-Panel Door Limit-Switch (44MG)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
R No specific circuit breaker(s) safety clip(s) No specific warning notices No specific access platform 3 m (9 ft. 10 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 38-31-13-991-001 Fig. 401
3. Job Set-up
__________
Subtask 38-31-13-861-050
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001)
R **ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-13-865-053
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-13-865-053-A
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-13-865-053-B
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C ALL
Subtask 38-31-13-010-051
C. Get Access
(1)
Put the access platform below the waste service panel.
(2)
Open the waste service-panel door 171AR.
(3)
Put the warning notices in position to tell persons not to operate the toilets.
(4)
Open the AFT cargo-compartment door (Ref. TASK 52-30-00-860-001).
(5)
Open the access door 162DW.
(6)
Set the CARGO COMP light-switch 8LU on the service panel 2024VU to the ON position.
4. Procedure
_________
(Ref. Fig. 401/TASK 38-31-13-991-001) Subtask 38-31-13-020-050
A. Removal of the Waste Service-Panel Door-Switch 44MG
(1)
Disconnect the electrical connector 44MG-A (1).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(45)