On the FAP:
-
The message CHECK LAVATORY-POWER SUPPLY: LAV XX shows on the toilet page.
In the vacuum toilet system:
-the vacuum generator 37MG will not operate.
-approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
-the toilet flush valve opens and the water drains out of the toilet bowl.
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 38-31-00-080-051
A. Removal of the Test Equipment
(1)
Bring the pressure on the altitude pressure switch 43MG back to ground level.
(2)
Remove the pitot static tester and the adapter from the altitude pressure switch 43MG.
R **ON A/C 106-149, 301-399, 401-499,
Subtask 38-31-00-080-051-A
A. Removal of the Test Equipment
(1) Bring the pressure on the pitot static tester back to ground level.
(2) Remove the pitot static tester. **ON A/C ALL
Subtask 38-31-00-860-051
B. Push the MCDU MENU mode key on the MCDU to return the system to the menu mode.
Subtask 38-31-00-613-060
C. Do the servicing of the toilet system (Ref. TASK 12-16-38-613-001). **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 38-31-00-410-051
D. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access panels 312AR, 172AR.
(3)
Remove the access platform(s).
R **ON A/C 106-149, 301-399, 401-499,
Subtask 38-31-00-410-051-A
D. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access panels 172AR.
(3) Remove the access platform(s).
**ON A/C ALL
Subtask 38-31-00-862-052
E. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
TASK 38-31-00-740-001
BITE Test of the Vacuum Toilet System
WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R R 24-42-00-861-001 24-42-00-862-001 31-32-00-860-001 Energize the Ground Service Network from the External PowerDe-energize the Ground Service Network Supplied from the External Power Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
3. Job Set-up__________
R Subtask 38-31-00-860-071
R A. Aircraft Maintenance Configuration
R R (1) Energize the ground service network (Ref. TASK 24-42-00-861-001).
R R (2) Energize the Central Fault Display System (CFDS) (Ref. TASK 31-32-00-860-001).
R **ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-00-865-102
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-00-865-102-A
B. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(15)