• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:21来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 **ON A/C ALL
 4. Procedure_________
 **ON A/C 001-003, 051-052,
 (Ref. Fig. 402/TASK 38-32-42-991-003) 
R  **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 402A/TASK 38-32-42-991-003-A)

 

 **ON A/C 001-003, 051-052,

 Subtask 38-32-42-420-051
 A. Installation of the drain valve in the washbasin.
 (1) Put the new packing (9) and the valve body (8) in position on the washbasin, make sure that the identification marks are aligned.
 (2) Install the collar (10) and the nut (11). R (3) TORQUE the nut (11) to 0.35 m.daN (30.97 lbf.in) maximum.
 (4)
 Put the plate assembly (4) in position.

 (5)
 Install the screws (6) and the washers (5).

 (6)
 Install a new O-ring (2) on the shaft of the operating handle (1).

 (7)
 Put the operating handle (1) in position and install the grubscrew (3).

 (8)
 Install a new O-ring (17) on the plug assembly (16).

 (9)
 Installation of the plug assembly (16).

 (a)
 Put the plug assembly (16) in position in the tube (7).

 (b)
 Install the spring (15), the tube (14), the washer (13) and the new retainer (12).

 

 

R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 38-32-42-420-051-A
 A. Installation of the drain valve in the washbasin.
 (1)
 Put the new gasket (6) and the valve body (7) in position on the washbasin (5), make sure that the identification marks are aligned.

 (2)
 Install the collar nut (4).

 (3)
 Tighten the collar nut (4) to between 1/8 and max 1/4 turn.

 (4)
 Install the filter (3) in the drain valve.

 (5)
 Install a new O-ring (2) on the strainer plug (1).
 NOTE : The O-ring (2) has a much smaller diameter.


____ You must be very careful when you expands it to install it on the strainer plug (1).

 (6)
 Install the strainer plug (1) in the collar nut.

 (7)
 Put the hose (8) in position and install the clamp (9).

 


 (8) Install the stopper (10). **ON A/C 001-003, 051-052,
 Subtask 38-32-42-820-050
 B. Adjustment of the Control Cable
 (Ref. Fig. 403/TASK 38-32-42-991-004)

 (1)
 Adjust the close position.

 (a)
 Put the operating handle (26) in the close position.

 (b)
 Make sure that the lever (25) contacts the close stop.

 (c)
 Make sure that the plug (20) is closed.

 (d)
 Loosen but do not remove the nut (23).

 (e)
 Adjust the nut (21) and make sure that the distance between the lever (22) and the plug assembly rod (24) is between 0.5 mm (0.0196 in.) and 1.0 mm (0.0393 in.).

 (f)
 Tighten the nut (23).

 

 (2)
 Operate the operating handle (26) and make sure that the system operates smoothly.


 Subtask 38-32-42-410-055
 C. Install the washbasin assembly (Ref. TASK 38-32-43-400-002).
R 1EFF : ALL 1 38-32-42Page 416 1 1 Aug 01/05 1 1 1CES 1


 Control Cable Adjustment
 Figure 403/TASK 38-32-42-991-004

R 1EFF : 001-003, 051-052, 1 38-32-42Page 417 1 1 May 01/05 1 1 1CES 1 **ON A/C 001-049, 051-099, 101-105,


 Subtask 38-32-42-865-064-A
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU LAV FWD - HOT WATER 1MB F02 2001VU LAVATORY AFT HOT WATER 2MB B02 2001VU LAVATORY AFT HOT WATER 9MB B03
 **ON A/C 106-149, 201-299,
 Subtask 38-32-42-865-064-B
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU LAV FWD - HOT WATER A 1MB F02 2001VU LAVATORY AFT - HOT WATER D 2MB B02 2001VU LAVATORY AFT - HOT WATER E 9MB B03
 **ON A/C 151-199,
 Subtask 38-32-42-865-064-C
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU LAV FWD - HOT WATER 1MB F02 2001VU LAVATORY AFT - HOT WATER D 2MB B02 2001VU LAVATORY AFT - HOT WATER E 9MB B03
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(128)