 C. Drainmast (Heated) (Ref: 30-71-00) The pressure difference between the cabin and the drainmasts outlet discards the waste water through the drainmasts in flight. Gravity discards the waste water through the drainmasts on the ground. The two masts have integrated electrical heating-elements to prevent the water from freezing during high-altitude flights or during cold weather. The heating elements are connected to the aircraft electrical network.


 WASTE WATER DRAIN - ADJUSTMENT/TEST
___________________________________
 TASK 38-32-00-710-002
 Operational Test of the Waste/Water Drain System
 NOTE : The operational test in a lavatory is given. The procedure is the same____ for all the other lavatories.
 1. Reason for the Job__________________
 Self Explanatory
 2. Job Set-up Information______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
R  No specific No specific No specific No specific  blanking plugscircuit breaker(s) safety clip(s)shutoff valve assemblycontainer 20 l (5.2833 USgal)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R R R R R R R  12-15-38-613-001 24-41-00-861-002 24-41-00-862-002 52-30-00-860-001 52-30-00-860-002 53-22-14-000-001 53-22-14-400-001  Fill the Potable Water Tank System (Aircraft Electrical Power Available)Energize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External Power Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump Removal of the FWD Cargo-Compartment Floor-Panels Installation of the FWD Cargo-Compartment Floor-Panels


 3. Job Set-up
__________

 Subtask 38-32-00-861-051
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 38-32-00-010-050
 B. Get Access
 (1) Open the lavatory door.
 **ON A/C 051-051,

 Subtask 38-32-00-010-050-A
 B. Get Access
 (1)
 Open the lavatory door.

 (2)
 Open the FWD cargo compartment door (Ref. TASK 52-30-00-860-001).


 (3) Remove the floor panel 131SF (Ref. TASK 53-22-14-000-001).
 **ON A/C 001-049, 051-099, 101-149, 201-299,

 Subtask 38-32-00-865-054-F
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2000VU WATER SYS - QUANT IND 1MA B01 2001VU WATER SYS - DRAIN 1MP B05

R **ON A/C 151-199, 301-399, 401-499,
 Subtask 38-32-00-865-054-E
 C. Make sure that this(these) circuit breaker(s) is(are) closed:


 -------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SYS - QUANT IND 1MA B06 2001VU WATER SYS - DRAIN 1MP B05

R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 38-32-00-860-054
 D. Preparation for Test
 (1)
 Fill the potable water system (Ref. TASK 12-15-38-613-001).

 (2)
 Install the shutoff valve assembly in the relevant drain mast.

 (3)
 Put the open end of the hose in a container.


 (4) Close the shutoff valve assembly at the drain mast.
 **ON A/C 051-051,

 Subtask 38-32-00-860-054-A
 D. Preparation for Test
 (1)
 Fill the potable water system (Ref. TASK 12-15-38-613-001).

 (2)
 Install the shutoff valve assembly in the relevant drain mast.

 (3)
 Put the open end of the hose in a container.

 (4)
 Close the shutoff valve assembly at the drain mast.

 (5)
 Disconnect the cargo compartment drain system at the drain mast 4MU.


 (6) Put blanking plugs on the disconnected line ends. R **ON A/C 001-049, 101-105, 151-199, 301-399, 401-499,
 Subtask 38-32-00-865-051
 E. Open, safety and tag this(these) circuit breaker(s):


 -------------------------------------------------------------------------------
 