the vacuum generator 37MG starts to operate.
-approx. 0.2 l (0.05 USgal) of water flows into one toilet bowl.
-air flows out of the ventilation port of the vacuum generator.
-the toilet flush valve (of the same toilet) opens and the suction removes the water.
R 1EFF : 001-049, 051-056, 1 38-31-00Page 509 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - within 10 s after the flush
R cycle starts, push the flush
R switch 51MG in the same and/or
R a different lavatory again.
R
R
R
R
R 4. On the altitude pressure switch
R 43MG:
R - set the altitude to 18000 +100-
R 100 ft. (5486.29 +30.47 -30.47
R m).
R 5. In one lavatory:
R - push the flush switch 51MG.
R
R
R
R
R
R 6. On the altitude pressure switch
R 43MG:
R - set the altitude to 16000 ft.
R (4876.71 m).
R 7. In a different lavatory:
R - push the flush switch 51MG.
R
R
R
R
R
R
R
-the vacuum generator continues to operate (first flush cycle not finished).
-a second or additional flush cycle does not start.
-the next flush cycle sequence is prevented for approx. 15 s after the first flush cycle starts.
In the vacuum toilet system:
-the vacuum generator 37MG will not operate.
-approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
-the toilet flush valve opens and the water drains out of the toilet bowl.
In the vacuum toilet system:
-the vacuum generator 37MG starts to operate.
-approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
-air flows out of the ventilation port of the vacuum generator.
-the toilet flush valve opens and the suction removes the water.
R 1EFF : 052-055, 1 38-31-00Page 510 1 1 May 01/05 1 1 1CES 1
R **ON A/C 057-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 38-31-00-710-053-A
A. Do this test.
NOTE : Make sure that the access panel 172AR is closed or the limit
____
switch 44MG is pushed and hold in during the test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In all lavatories: In the vacuum toilet system:
- push each flush switch 51MG - the vacuum generator 37MG starts to
with a time delay of 15 +3 -3 operate each time when the flush
s. switch is pressed.
- approx. 0.2 l (0.05 USgal) of water
flows into the toilet bowl.
- air flows out of the ventilation port
of the vacuum generator.
- the toilet flush valve opens and the
suction removes the water.
2. In two lavatories: In the vacuum toilet system:
- push the flush switches 51MG - the vacuum generator 37MG starts to
within 7 s. operate.
- approx. 0.2 l (0.05 USgal) of water
flows into one toilet bowl.
- air flows out of the ventilation port
of the vacuum generator.
- the toilet flush valve (of the same
toilet) opens and the suction removes
the water.
3. In a lavatory: In the vacuum toilet system:
- Operate the flush switch 51MG - the vacuum generator does not
while the waste service panel operate.
is open. - the flush does not occur.
- on the FAP the message VACUUM SYSTEM
DISABLED-GROUND SERVICING is shown.
4. In the aircraft system: In the vacuum toilet system:
- Simulate a cabin differential - The vacuum generator remains switched
pressure of 260 mbar (3.77 off.
psi). - The flush occurs as required.
R 1EFF : 057-099, 101-149, 151-199, 201-299, 1 38-31-00Page 511 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Operate the flush switch 51MG in one toilet.