REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R **ON A/C 106-149, 301-399, 401-499,
38-31-00-991-017-A Fig. 501A
**ON A/C ALL
3. Job Set-up
__________
Subtask 38-31-00-861-052
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 38-31-00-010-052
B. Get Access
(1)
Put the ACCESS PLATFORM 3M (10 FT) below the access panel 312AR.
(2)
Put the ACCESS PLATFORM 2M (6 FT) below the access panel 172AR.
(3) Open the access panels 312AR, 172AR. R **ON A/C 106-149, 301-399, 401-499,
Subtask 38-31-00-010-052-A
B. Get Access
(1)
Put the ACCESS PLATFORM 2M (6 FT) below the access panel 172AR.
(2)
Open the access panels 172AR.
**ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-00-865-101
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-00-865-101-A
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-00-865-101-B
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 38-31-00Page 503 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
Subtask 38-31-00-613-052
D. Fill the potable water tank system (Ref. TASK 12-15-38-613-001).
Subtask 38-31-00-680-053
E. Drain the toilet system (Ref. TASK 38-31-00-680-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 38-31-00-480-051
F. Installation of the Test Equipment
(1)
Install the ADAPTER - ALTITUDE PRESSURE SWITCH on the altitude pressure switch 43MG.
(2)
Connect the TEST UNIT - STATIC PITOT to the altitude pressure switch-adapter.
Subtask 38-31-00-860-050
G. Simulate the LGCIU 2 in the flight configuration on the CFDS (Ref. TASK 32-69-00-860-001).
R **ON A/C 106-149, 301-399, 401-499,
Subtask 38-31-00-480-051-A
F. Installation of the Test Equipment
(1) Connect the TEST UNIT - STATIC PITOT to the static port.
Subtask 38-31-00-860-050-A
G. Preparation for Test
(1)
Simulate the LGCIU 2 in the flight configuration on the CFDS (Ref. TASK 32-69-00-860-001).
(2)
Make sure that the TOILET page is shown on the CFDS.
(3)
Make sure that there are no failure in the fault memory of the CFDS.
**ON A/C ALL
4. Procedure
_________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(12)