 5. On the FCU tester IIA:
-put the ENABLE/DISABLE switch to the DISABLE position.
-
the toilet flush cycle functions and the toilet flushes.

In the vacuum system:

-
the vacuum blower does not operate.

-
the flush valve operates and 0.2 l


(0.05 USgal) of water flows into thetoilet bowl.
 NOTE : At the end of each flush cycle
____ the status of the toilet is updated. The NO FAULT light will stay on if no faults are found during this cycle.
On the FCU tester IIA:
-
the NO FAULT light goes off.

-
the NO POWER to FCU or DISABLE light is on.


 NOTE : If necessary you can cancel a
____ flush cycle when you push the RESET pushbutton.
 NOTE : During the complete test:
____
 -
the TOILET INOP light on the Flight Attendant Panel (FAP) is on.

 -
the Vacuum System Controller (VSC) receives no data that the FCU is powered, this is normal and should be ignored,

 -
the VSC has no effect on the toilet operation, but will still control the vacuum blower.

 -
the faults shown are not stored in the VSC Electrically Erasable Programmable Read Only Memory (EEPROM).


R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 38-31-00Page 536 1201-299, 1May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------NOTE : The FCU tester IIA is defective
____ if:
 -two or more red lights are ON,
 -the NO FAULT light and also one of the red lights are ON.

R **ON A/C 106-149, 301-399, 401-499,
 Subtask 38-31-00-720-050-A
 A. Do this Test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the FCU tester IIA:  On the FCU tester IIA:
 - put the power switch to the POWER position.  - the green light INPUT POWER comes on.- the NO FAULT light comes on and stays
 on.
 NOTE : If the NO FAULT light goes off____ after a few seconds (then there is a fault in the system) and one of the subsequent lights will come on:
 - the open position limit switch, - the close position limit switch, - the rinse water solenoid, - the FCU internal faults, - the flush valve motor, - the no power to FCU or disabled.
 2. On the FCU tester IIA:  On the FCU tester IIA:
 - push the flush pushbutton.  - the FLUSH CYCLE light comes ON.
 In the vacuum system: - the vacuum blower operates for 15 s. - the toilet flush cycle functions and the toilet flushes.

 

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
3. On the FCU tester:
-turn the blower switch to the BLOWER OFF position.
-push and hold the flush pushbutton.
4. On the FCU tester IIA:
 -release the blower switch to the NORMAL position.
 5. On the FCU tester IIA:
-put the ENABLE/DISABLE switch to the DISABLE position.
In the vacuum system:
-
the vacuum blower does not operate.

-
the flush valve operates and 0.2 l


(0.05 USgal) of water flows into thetoilet bowl.
 NOTE : At the end of each flush cycle
____ the status of the toilet is updated. The NO FAULT light will stay on if no faults are found during this cycle.
On the FCU tester IIA:
-
the NO FAULT light goes off.

-
the NO POWER to FCU or DISABLE light is on.


 NOTE : If necessary you can cancel a
____ flush cycle when you push the RESET pushbutton.
 NOTE : During the complete test:
____
 -
the VACUUM SYSTEM DISABLED message on the WATER/WASTE page on the Flight Attendant Panel (FAP) is shown.

 -
the DUE B receives no data that the FCU is powered, this is normal and should be ignored,


 NOTE : The FCU tester IIA is defective
____ if:
 -two or more red lights are ON,
 -the NO FAULT light and also one of the red lights are ON.
R 1EFF : 106-149, 301-399, 401-499, 1 38-31-00Page 538 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 5. Close-up
________ Subtask 38-31-00-410-067
 A. Close Access
 (1)
 Disconnect the electrical connector 50MG-A, 50MG1-A, 50MG2-A 50MG3-A or 50MG4-A from the FCU tester IIA.

 (2)
 Disconnect the electrical connector of the FCU tester IIA from the FCU.

 (3)
 Remove the FCU tester IIA.
 