• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:21来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R **ON A/C 106-149, 151-199, 201-299,
 Subtask 38-31-63-865-060-A
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
 tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08


R  **ON A/C 301-399, 
R  Subtask 38-31-63-865-060-B 
R R R R R R R R R R R  B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
 **ON A/C ALL
 4. Procedure_________
 (Ref. Fig. 401/TASK 38-31-63-991-001)
 Subtask 38-31-63-420-051
 A. Installation of the liquid Level Sensor 41MG
 (1) Put the new O-ring (4) in position.
 (2) Put the liquid level sensor 41MG (3) in position.
 (3) Make sure that the location pin is at the top.
 (4) Install the washers (5) and the nuts (6) and tighten.
 (5) TORQUE the nuts (6) to between 0.079 m.daN (7 lbf.in) and 0.11 m.daN (10 lbf.in).
 (6) Remove the blanking cap and connect the electrical connector 41MG-A (2).
 Subtask 38-31-63-720-051
 B. Do the functional test of the liquid level sensor 41MG and transmitter 40MG (Ref. TASK 38-31-00-720-002)

 

 5. Close-up
________ Subtask 38-31-63-613-051
 A. Do the servicing of the waste holding tank (Ref. TASK 12-16-38-613-001). Subtask 38-31-63-410-052
 B. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the access panels 161DW, 162DW.

 (3)
 Remove the access platform(s).


 (4) Close the AFT cargo-compartment door (Ref. TASK 52-30-00-860-002). Subtask 38-31-63-862-051
 C. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).

 

 GENERATOR - VACUUM - REMOVAL/INSTALLATION
_________________________________________
 TASK 38-31-64-000-001
 Removal of the Vacuum Generator 37MG
 WARNING : DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER
_______ SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
 WARNING : ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
_______
 -
ON THE TOILET WASTE SYSTEM, OR


 -
ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
 WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND
 WATER.
 THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).

 

 WARNING : WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS PUT IT
_______ IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST, THEN ATTACH THE DOCUMENT TO IT. THIS WILL PREVENT INFECTION (CONTAMINATION FROM TOILET WASTE CAN BE DANGEROUS TO HEALTH).
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s) R R No specific 2 ACCESS PLATFORM 2M (6 FT)


 B. Consumable Materials

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 14-001A DEODORANT AIRCRAFT TOILET NON FORMALDE- HYDE BASE (Ref. 20-31-00)
 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(85)