(2)
Put blanking caps on the disconnected electrical connectors.
(3)
Remove and discard the locking wire from the nut (4).
(4)
Remove the nut (4) and the washer (3).
(5)
Remove the switch (2).
1EFF : ALL 1 38-31-13Page 403 1 1 Feb 01/05R 1 1 1CES 1
Waste Service-Panel Door Limit-Switch (44MG) Figure 401/TASK 38-31-13-991-001
1EFF : 1 1R 1CES ALL 1 11 1 38-31-13 Page 404 Aug 01/01
TASK 38-31-13-400-001
Installation of the Waste Service-Panel Door Limit-Switch (44MG)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notices
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R Material No. 19-009 USA AMS 5687 R LOCKWIRE STAINLESS STEEL ANNEALED 0.5MM DIA R (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power 38-31-00-710-008 Operational Test of the Door Limit Switch 44MG 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
38-31-00-820-001 Adjustment of the Contact Point of the Waste
Service-Panel-Door Limit-Switch (44MG) (for
corrective action)
38-31-13-991-001 Fig. 401
3. Job Set-up
__________
Subtask 38-31-13-860-050
A. Aircraft Maintenance Configuration
(1)
Make sure that the waste service-panel door 172AR is open.
(2)
Make sure that the AFT cargo-compartment door is open (Ref. TASK 52-30-00-860-002).
(3)
Make sure that the access door 162DW is open.
(4)
Make sure that the the access platform is in position below the waste service panel.
(5)
Make sure that the ground service network is energized from the external power (Ref. TASK 24-42-00-861-001).
(6)
Make sure that the CARGO COMPT light-switch 8LU is set to the ON position.
(7)
Make sure that the warning notices are in position to tell persons not to operate the toilets.
R **ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-13-865-055
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-13-865-055-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-13-865-055-B
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08