4. Procedure
_________
**ON A/C 001-049, 051-099, 101-149, 201-299,
(Ref. Fig. 301/TASK 38-41-00-991-001) R **ON A/C 151-199, 301-399, 401-499,
(Ref. Fig. 301A/TASK 38-41-00-991-001-A)
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 38-41-00-020-050
A. Removal of the Cartridge (3)
(1)
Remove the tube (1).
(2)
Cut and remove the lockwire from the cap.
Air Filter 4210MM
Figure 301/TASK 38-41-00-991-001
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-41-00Page 304 1 1 May 01/05 1 1 1CES 1
Air Filter 4210MM Figure 301A/TASK 38-41-00-991-001-A
R 1EFF : 151-199, 301-399, 401-499, 1 38-41-00Page 305 1 1 Aug 01/05 1 1 1CES 1
(3)
Remove the cap (2).
(4)
Remove and discard the cartridge (3) from the filter 4210MM (6).
(5) Remove and discard the O-rings (4) and (5). R **ON A/C 151-199, 301-399, 401-499,
Subtask 38-41-00-020-050-A
A. Removal of the Cartridge (3)
(1)
Remove the clamp (7).
(2)
Remove the tube (1).
(3)
Cut and remove the lockwire from the cap.
(4)
Remove the cap (2).
(5)
Remove and discard the cartridge (3) from the filter 4210MM (6).
(6) Remove and discard the O-rings (4) and (5).
**ON A/C ALL
Subtask 38-41-00-110-050
B. Clean the component interface and/or the adjacent area. WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
(1) Clean all metal parts with CLEANING AGENTS (Material No. 11-008).
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 38-41-00-420-050
C. Installation of the Cartridge (3)
(1)
Put a new O-ring (5) into the filter 4210MM (6).
(2)
Put a new O-ring (4) onto the new cartridge (3).
(3)
Put the new cartridge (3) into the filter 4210MM (6).
(4)
Install the cap (2).
(5)
Safety the cap with corrosion-resistant steel lockwire 0.8 mm(0,032 in)dia.
(6) Install the tube (1). R **ON A/C 151-199, 301-399, 401-499,
Subtask 38-41-00-420-050-A
C. Installation of the Cartridge (3)
(1)
Put a new O-ring (5) into the filter 4210MM (6).
(2)
Put a new O-ring (4) onto the new cartridge (3).
(3)
Put the new cartridge (3) into the filter 4210MM (6).
(4)
Install the cap (2).
(5)
Safety the cap with corrosion-resistant steel lockwire 0.8 mm(0,032 in)dia.
(6)
Install the tube (1).
(7)
Install the clamp (7).
**ON A/C ALL
Subtask 38-41-00-710-053
D. Test
(1)
Do the leak check of the component (Ref. TASK 38-41-00-790-001).
(2)
Do the operational test of the system and make sure it operates correctly (Ref. TASK 38-41-00-710-001).
5. Close-up
________
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 38-41-00-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
If necessary apply SPECIAL MATERIALS (Material No. 05-027) to the components and structure (Ref. TASK 51-75-13-916-001).
(3)
Install the access panel 131PW.
(4)
Remove the access platform(s).
(5) Close the FWD cargo-compartment door (Ref. TASK 52-30-00-860-002). R **ON A/C 151-199, 301-399, 401-499,
Subtask 38-41-00-410-050-A
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
If necessary apply SPECIAL MATERIALS (Material No. 05-027) to the components and structure (Ref. TASK 51-75-13-916-001).