R Subtask 38-31-61-170-050
R D. Flush the waste holding tank with clean water.
R (1) Listen and make sure that you can hear water spray against the wall
R of the waste holding tank.
R Subtask 38-31-61-680-054
R E. Drain the waste holding tank (Ref. TASK 38-31-00-680-001).
R Subtask 38-31-61-790-052
R F. Do the leak test of the vacuum toilet system and record the result of the
R test (Ref. TASK 38-31-00-790-002).
R **ON A/C 001-049, 051-099, 101-105,
R Subtask 38-31-61-865-064
R G. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04
R 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06
R 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 106-149, 151-199, 201-299,
R Subtask 38-31-61-865-064-A
R G. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04
R 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06
R 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 301-399,
R Subtask 38-31-61-865-064-B
R G. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL SERVICE IDENT. LOCATION
R -------------------------------------------------------------------------------
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03
R 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04
R 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06
R 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C ALL
R Subtask 38-31-61-010-057
R H. Get Access
R (1) Open the Waste Holding Tank
R (Ref. Fig. 601/TASK 38-31-61-991-003)
R (a) Remove the screws (10) and the cover (11).
R (b) Discard the O-ring (12).
4. Procedure_________
Subtask 38-31-61-210-053
A. Inspection
WARNING : ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN_______
YOU DO THIS TASK.
(1) Use a strong FLASHLIGHT and MIRROR - INSPECTION, FLEXIBLE to do this
task.
R (2) Inspect the rinse nozzles for waste build up or damage.
R (a) If you did not hear water spray against the wall of the waste
R holding tank refer to step 3.D.(1).
R
Waste Holding Tank Assemly Figure 601/TASK 38-31-61-991-003
1EFF : 1 1R 1CES ALL 1 11 1 38-31-61 Page 606 Feb 01/05
R (b) If there is waste build up, remove the rinse assembly and clean
R as follows.
R
(Ref. Fig. 601/TASK 38-31-61-991-003)
R
R 1_ Remove the nuts (1) and the washers (2) and remove the rinse
R assembly (9).
R
R 2_ Disinfect the rinse assembly (9) with DISINFECTANTS (Material
No. 14-008).
R
R 3_ Remove the retaining ring (7) and remove the nozzle (6)
R together with the teflon washers (5).
R