 C. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).

 Subtask 38-31-00-942-064
 D. Remove the ground support and maintenance equipment, the special and standard tools and all other items.


 TOILET SYSTEM - CLEANING/PAINTING
_________________________________
 TASK 38-31-00-100-003
 Cleaning of the Waste Holding Tank
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE SPECIAL
_______
 MATERIAL.
 THIS MATERIAL IS DANGEROUS.

 WARNING : ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO
_______
 THIS TASK.

 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific internal tank cleaner-VACLAV Cleaner
 No specific metal adapter
 No specific packing
 No specific tank cover adapter-VACLAV Cleaner

R No specific 1 ACCESS PLATFORM 2M (6 FT)
R No specific 1 CLEANING EQUIPMENT VACLAV - TANK, INTERNAL
R No specific 1 CONTAINER 3 L(3/4 USGAL)

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-012 USA VV-P-236 PURE MINERALVASELINE OR PETRO- LATUM (Ref. 20-31-00) Material No. 08-007B C Z-15.502 SEALANT, HIGH TEMP. (Ref. 20-31-00)
 Material No. 14-001A DEODORANT AIRCRAFT TOILET NON FORMALDE- HYDE BASE (Ref. 20-31-00)


 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
 -------------------------------------------------------------------------------
4 O-ring 38-31-61 15 -020 4 O-ring 38-31-61 15 -020A
 D. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
12-16-38-613-001 Servicing of the Toilet System 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 38-31-00-680-001 Draining of the Toilet System
R 38-31-00-790-002 Leak Test of the Vacuum Toilet System 38-31-62-000-001 Removal of the Liquid Level Transmitter (40MG) 38-31-62-400-001 Installation of the Liquid Level Transmitter (40MG) 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 38-31-00-991-005 Fig. 701 38-31-00-991-006 Fig. 702
 3. Job Set-up
__________
 Subtask 38-31-00-861-066
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 Subtask 38-31-00-010-060
 B. Get Access
 (1)
 Open the AFT cargo-compartment door (Ref. TASK 52-30-00-860-001).

 (2)
 Put the ACCESS PLATFORM 2M (6 FT) in position at Zone 172.

 (3)
 Remove the access panel 162DW.

 


 Subtask 38-31-00-680-055
 C. Drain the toilet system (Ref. TASK 38-31-00-680-001), but do not remove the service vehicle.

R **ON A/C 001-049, 051-099, 101-105,
 Subtask 38-31-00-865-075
 D. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08

R **ON A/C 106-149, 151-199, 201-299,
 Subtask 38-31-00-865-075-A
 D. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
 