R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
4. Procedure
_________
(Ref. Fig. 401/TASK 38-31-69-991-001)
Subtask 38-31-69-420-050
A. Installation of the Altitude Pressure Switch 43MG
(1)
Clean the component interface and/or the adjacent area.
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Install the altitude pressure switch (1).
(4)
Install the washers (3) and the bolts (4).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 38-31-69Page 406 1201-299, 1May 01/05 1 1 1CES 1
(5) Make sure that the electrical connectors are clean and in the correct
condition.
(6) Connect the electrical connector (5). Subtask 38-31-69-710-050
B. Do the operational test of the toilet system (Ref. TASK 38-31-00-710-002).
5. Close-up
________ Subtask 38-31-69-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access door 312AR.
(3) Remove the access platform(s). Subtask 38-31-69-862-050
B. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 38-31-69Page 407 1201-299, 1May 01/05 1 1 1CES 1
VALVE - WASTE DRAIN (3340MM) - REMOVAL/INSTALLATION
___________________________________________________
TASK 38-31-71-000-001
Removal of the Waste Drain Valve 3340MM
WARNING : DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER
_______ SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING : ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
_______
-
ON THE TOILET WASTE SYSTEM, OR
-
ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND
WATER.
THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING : WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS PUT IT
_______ IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST, THEN ATTACH THE DOCUMENT TO IT. THIS WILL PREVENT INFECTION (CONTAMINATION FROM TOILET WASTE CAN BE DANGEROUS TO HEALTH).
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs R No specific circuit breaker(s) safety clip(s) No specific 1 ACCESS PLATFORM 2M (6 FT)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power 38-31-00-680-001 Draining of the Toilet System 38-31-00-790-002 Leak Test of the Vacuum Toilet System 38-31-74-000-001 Removal of the Waste Tank Drain Line 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
38-31-71-991-001 Fig. 401
**ON A/C 051-051,
38-31-71-991-001-A Fig. 401A
**ON A/C ALL
3. Job Set-up
__________
Subtask 38-31-71-861-050