 Install the screws (4), the washers (5) and the nuts (6).

 (4)
 Install the bolt (1).


 (5)
 Install the washer (2) and the nut (3).

 


 Subtask 38-31-73-210-050
 B. Inspection
 (1)
 Make sure that the drain valve is completely opened when the control lever 3341MM (7) is in the DRAIN position.

 (2)
 Make sure that the drain valve is completely closed when the control lever 3341MM (7) is in the NORMAL position.


 Subtask 38-31-73-613-050
 C. Fill the waste holding tank 3300MM with 13.5 l (3.5662 USgal) of DISINFECTANTS (Material No. 14-001A).
 5. Close-up
________

R **ON A/C 001-049, 051-099, 101-105,
 Subtask 38-31-73-865-061
 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08

R **ON A/C 106-149, 151-199, 201-299,
 Subtask 38-31-73-865-061-A
 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):


 -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08 
R  **ON A/C 301-399, 
R  Subtask 38-31-73-865-061-B 
R R R R R R R R R R R  A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
 **ON A/C ALL
 Subtask 38-31-73-410-050
 B. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Close the access panel 162DW.
 (3) Close the waste service panel 172AR.
 (4) Close the AFT cargo-compartment door (Ref. TASK 52-30-00-860-002).
 (5) Remove the access platform(s).

 

 Subtask 38-31-73-862-050

 C. De-energize the ground service network (Ref. TASK 24-42-00-862-001).


 DRAIN LINE - TANK - REMOVAL/INSTALLATION
________________________________________
 TASK 38-31-74-000-001
 Removal of the Waste Tank Drain Line
 WARNING : DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER
_______ SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
 WARNING : ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
_______
 -
ON THE TOILET WASTE SYSTEM, OR

 -
ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
 WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND
 WATER.
 THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).

 

 WARNING : WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS PUT IT
_______ IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST, THEN ATTACH THE DOCUMENT TO IT. THIS WILL PREVENT INFECTION (CONTAMINATION FROM TOILET WASTE CAN BE DANGEROUS TO HEALTH).
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs R No specific circuit breaker(s) safety clip(s) No specific 1 ACCESS PLATFORM 2M (6 FT)
 