Subtask 38-31-00-942-063
D. Remove the ground support and maintenance equipment, the special and standard tools and all other items.
R 1EFF : ALL 1 38-31-00Page 556 1 1 May 01/05 1 1 1CES 1
TASK 38-31-00-720-002
Functional Test of the Liquid Level Sensor 41MG and Transmitter 40MG
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 3M (10 FT)
No specific 1 CART - SERVICING, TOILET
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-16-38-613-001 Servicing of the Toilet System 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power R 38-31-00-680-001 Draining of the Toilet System
3. Job Set-up
__________
Subtask 38-31-00-861-061
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 38-31-00-010-073
B. Get Access
(1)
Get access to the cabin.
(2)
Put an ACCESS PLATFORM 3M (10 FT) in position under the waste service panel.
R 1EFF : ALL 1 38-31-00Page 557 1 1 May 01/05 1 1 1CES 1
(3) Open the waste service-panel door 172AR.
R **ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-00-865-108
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-00-865-108-A
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-00-865-108-B
C. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C ALL
Subtask 38-31-00-480-055
D. Connect a CART - SERVICING, TOILET to the flush-connection on the waste service panel.
R Subtask 38-31-00-680-068
R E. Make sure that the vacuum tank is drained (Ref. TASK 38-31-00-680-001)
4. Procedure
_________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 38-31-00-720-051
A. Do the Test of the liquid level Sensor 41MG and Transmitter 40MG.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the toilet service panel: - fill the waste holding tank 3300MM with 85 +5 -5 l (22.45 +1.32 -1.32 USgal) of water. On the Forward Attendant Panel (FAP)120RH/miscellaneous panel WATER ANDWASTE 124RH:- the waste level indicator indicates 50% on the scale.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(26)