(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels 161DW, 162DW (Ref. TASK 25-55-12-400-001).
(3)
Remove the access platform(s).
(4) Close the aft cargo compartment door (Ref. TASK 52-30-00-860-002). Subtask 38-31-64-862-051
B. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
CHECK - VALVE (3320MM) - REMOVAL/INSTALLATION
_____________________________________________
TASK 38-31-65-000-001
Removal of the Check Valve 3320MM
WARNING : DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER
_______ SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING : ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
_______
-
ON THE TOILET WASTE SYSTEM, OR
-
ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND
WATER.
THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING : WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS PUT IT
_______ IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST, THEN ATTACH THE DOCUMENT TO IT. THIS WILL PREVENT INFECTION (CONTAMINATION FROM TOILET WASTE CAN BE DANGEROUS TO HEALTH).
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs R No specific circuit breaker(s) safety clip(s) No specific 1 ACCESS PLATFORM 2M (6 FT)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
38-31-65-991-001 Fig. 401
**ON A/C 051-051,
38-31-65-991-001-A Fig. 401A
**ON A/C ALL
3. Job Set-up
__________
Subtask 38-31-65-861-050
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
**ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-65-865-056
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-65-865-056-A
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-65-865-056-B
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------