(1) Put the ACCESS PLATFORM 2M (6 FT) in position. Subtask 38-31-64-680-051
B. Drain Flush and Disinfect the Waste System
(1)
Drain and flush the waste tank (Ref. TASK 38-31-00-680-001).
(2)
Put 2. l (0.5283 USgal) of DISINFECTANTS (Material No. 14-001A) in each toilet bowl and flush them through.
NOTE : This procedure is to make sure that the complete toilet system
____
is disinfected.
1EFF : ALL 1 38-31-64Page 402 1 1 May 01/02R 1 1 1CES 1
R **ON A/C 001-049, 051-099, 101-105,
Subtask 38-31-64-865-063
C. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
R **ON A/C 106-149, 151-199, 201-299,
Subtask 38-31-64-865-063-A
C. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C 301-399,
Subtask 38-31-64-865-063-B
C. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU VACUUM TOILET SYSTEM/LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER E 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08
**ON A/C ALL
Subtask 38-31-64-010-050
D. Get Access
(1)
Open the aft cargo-compartment door (Ref. TASK 52-30-00-860-001).
(2)
Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door 826.
(3)
Remove the cargo compartment panels 161DW, 162DW (Ref. TASK 25-55-12-000-001).
4. Procedure
_________
(Ref. Fig. 401/TASK 38-31-64-991-001) Subtask 38-31-64-020-051
A. Removal of the Vacuum Generator 37MG WARNING : ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN
_______
YOU DO THIS TASK.
WARNING : WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS
_______ PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST, THEN ATTACH THE DOCUMENT TO IT. THIS WILL PREVENT INFECTION (CONTAMINATION FROM TOILET WASTE CAN BE DANGEROUS TO HEALTH).
(1)
Disconnect the electrical connectors (1) 37MG-B and (2) 37MG-A.
(2)
Put blanking caps on the disconnected electrical connectors.
(3)
Remove the nut (11) and the washer (10).
(4)
Remove the bolt (8) and the bonding strap (9).
(5)
Remove the clamps (7) and the hose (6).
(6)
Remove the clamps (12) and the hose (13).
(7)
Remove the bolts (3) and the washers (4).
1EFF : ALL 1 38-31-64Page 404 1 1 May 01/05R 1 1 1CES 1
Vacuum Generator 37MG Figure 401/TASK 38-31-64-991-001
1EFF : 1 1R 1CES ALL 1 11 1 38-31-64 Page 405 Aug 01/01
(8) Remove the vacuum generator (5) 37MG.
1EFF : ALL 1 38-31-64Page 406 1 1 May 01/05R 1 1 1CES 1
TASK 38-31-64-400-001
Installation of the Vacuum Generator 37MG
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 2(86)