R FOR FIN 10LZ
R No specific stepladder 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
**ON A/C 001-049, 051-099, 101-149, 151-199, 211-299,
33-27-12-991-001 Fig. 401
**ON A/C 201-210,
33-27-12-991-001-B Fig. 401A
**ON A/C 301-399,
33-27-12-991-001-C Fig. 401B R **ON A/C 401-499,
R 33-27-12-991-001-A Fig. 401C **ON A/C ALL
3. Job Set-up
__________
Subtask 33-27-12-865-050
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU LIGHT - ATTND WORK 1LZ J03
**ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
Subtask 33-27-12-010-050
B. Get Access
(1)
FOR 4LZ, 5LZ
(a)
Put the stepladder in position below the related panel.
(b)
Lower the circuit breaker panel 2000VU.
(2)
FOR 10LZ, 11LZ, 15LZ
(a)
Put the stepladder in position below the related panel.
(b)
Lower the circuit breaker panel 2001VU.
(3)
FOR 14LZ
(a) Put the stepladder in position below the related panel.
(b) Disengage and lower one side of the combi panel 2042VU. **ON A/C 301-399,
Subtask 33-27-12-010-050-B
B. Get Access
(1)
FOR 204LZ, 205LZ
(a)
Put the stepladder in position below the related panel.
(b)
Lower the circuit breaker panel 2000VU.
(2)
FOR 210LZ, 211LZ, 215LZ
(a)
Put the stepladder in position below the related panel.
(b)
Lower the circuit breaker panel 2001VU.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 33-27-12Page 403 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1
(3) FOR 214LZ
R (a) Put the stepladder in position below the related panel. (b) Disengage and lower one side of the PSU 612RH. **ON A/C 401-499,
R R R R R R R R R R R Subtask 33-27-12-010-050-A B. Get Access (1) FOR 4LZ, 5LZ (a) Put the stepladder in position below the related panel. (b) Lower the circuit breaker panel 2000VU. (2) FOR 10LZ (a) Put the stepladder in position below the related panel. (b) Lower the circuit breaker panel 2001VU. (3) FOR 14LZ (a) Put the stepladder in position below the related panel. (b) Disengage and lower one side of the combi panel 2042VU. **ON A/C ALL
4. Procedure_________ **ON A/C 001-049, 051-099, 101-149, 151-199, 211-299,
(Ref. Fig. 401/TASK 33-27-12-991-001) **ON A/C 201-210,
(Ref. Fig. 401A/TASK 33-27-12-991-001-B)
Cabin Attendant Work-Light
Figure 401/TASK 33-27-12-991-001
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 33-27-12Page 405 1211-299, 1May 01/05 1 1 1CES 1
Cabin Attendant Work-Light
Figure 401A/TASK 33-27-12-991-001-B
R 1EFF : 201-210, 1 33-27-12 Page 406
1 1 May 01/04
1 1
1CES 1
**ON A/C 301-399,
(Ref. Fig. 401B/TASK 33-27-12-991-001-C) R **ON A/C 401-499,
R (Ref. Fig. 401C/TASK 33-27-12-991-001-A) **ON A/C ALL
Subtask 33-27-12-020-051
A. Removal of the Cabin Attendant Work-Lights
CAUTION : DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
_______ THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
(1)
Disconnect the electrical connectors (2) from the cabin attendant work-lights
(2)
Put blanking caps on the disconnected electrical connectors.