• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 00:04来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 **ON A/C 301-399,
 A. Cabin Illumination The cabin lamps are distributed in four strips throughout the cabin zones. The four strips in each cabin zone are divided for control purposes into two pairs. The two outboard strips are designated as WINDOW (WDO) lights and the two center strips as CEILING (CLG) lights. The system is designed
R 1EFF : 051-099, 151-199, 201-299, 301-399, 1 33-21-00Page 32 1 1 Aug 01/05 1 1 1CES 1 so that the window and ceiling lights in the cabin zone can be on together or separately. When on, the fluorescent lamps can be selected to 100 % (BRT), 50 % (DIM 1), or 10 % (DIM 2) intensity. Each fluorescent lamp is installed in a holder which contains an integral ballast unit. The units are supplied with 115VAC from busbars 212XP and 214XP through circuit breakers 300LG thru 307LG (cabin lighting) and 308LG (entrance lighting). The lighting system is controlled from the Flight Attendant Panel (FAP) 120RH and from the AFT Attendant Panel (AAP) 126RH.


 **ON A/C ALL
 B. Forward Attendat Panel (FAP)
 (1)
 MAIN ON - when pushed, switches on the cabin zones and entrance areas lighting with 100 % intensity. It also causes the integral light in all BRT, WDO and CLG membrane switches to come on.

 (2)
 MAIN OFF - when pushed, switches off the cabin zones and entrance areas lighting. It also causes any general illumination membrane switch which is on to go off. This function is disabled in flight.

 

R **ON A/C 001-049, 101-149, 201-210, 401-499,
 (3)
 ENTRY BRT - when initially pushed, causes the related entrance area lighting to come on with 100 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (4)
 ENTRY DIM1 - when initially pushed, causes the related entrance area lighting to come on with 50 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (5)
 ENTRY DIM2 - when initially pushed, causes the related entrance area lighting to come on with 10 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 


 **ON A/C 051-099,
 (3)
 ENTRY FWD BRT and ENTRY AFT BRT - when initially pushed, causes the related entrance area lighting to come on with 100 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (4)
 ENTRY FWD DIM1 and ENTRY AFT DIM1 - when initially pushed, causes the related entrance area lighting to come on with 50 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (5)
 ENTRY FWD DIM2 and ENTRY AFT DIM2 - when initially pushed, causes the related entrance area lighting to come on with 10 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 

R **ON A/C 151-199, 211-299,
 (3)
 ENTRY FWD BRT and ENTRY AFT BRT - when initially pushed, causes the related entrance area lighting to come on with 100 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (4)
 ENTRY FWD DIM1 and ENTRY AFT DIM1 - when initially pushed, causes the related entrance area lighting to come on with 50 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (5)
 ENTRY FWD DIM2 and ENTRY AFT DIM2 - when initially pushed, causes the related entrance area lighting to come on with 10 % intensity. It also causes the integral light under the membrane switch foil to come on. The lights may be switched off by pushing the membrane switch twice in succession.


R 1EFF : 051-099, 151-199, 211-299, 1 33-21-00Page 34 1 1 Aug 01/05 1 1 1CES 1

 **ON A/C 301-399,


 (3)
 ENTRY BRT - when initially pushed, causes the related entrance area lighting to come on with 100 % intensity. It also causes the integral light under the pushbutton foil to come on.

 (4)
 ENTRY DIM1 - when initially pushed, causes the related entrance area lighting to come on with 50 % intensity. It also causes the integral light under the pushbutton foil to come on.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光1(54)