• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 00:04来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (5)
 ENTRY DIM2 - when initially pushed, causes the related entrance area lighting to come on with 10 % intensity. It also causes the integral light under the pushbutton foil to come on.

 

R **ON A/C 001-049, 051-099, 101-149, 401-499,
 (6)
 BRT - when initially pushed, causes the related cabin zone lighting to come on with 100 % intensity. It also causes the integral lights in the related BRT, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (7)
 DIM1 - when initially pushed, causes the related cabin zone lighting to come on with 50 % intensity. It also causes the integral light in the related DIM 1, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.

 (8)
 DIM2 - when initially pushed, causes the related cabin zone lighting to come on with 10 % intensity. It also causes the integral light in the related DIM 2, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.


R
 **ON A/C 151-199,
 (6) BRT - when initially pushed, causes the related cabin zone lighting to come on with 100 % intensity. It also causes the integral lights in the related BRT, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 33-21-00Page 35 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 (7) DIM1 - when initially pushed, causes the related cabin zone lighting to come on with 50 % intensity. It also causes the integral light in the related DIM 1, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.
 (8) DIM2 - when initially pushed, causes the related cabin zone lighting to come on with 10 % intensity. It also causes the integral light in the related DIM 2, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession. 
R  **ON A/C 201-299, 
R R R R R  (6) BC BRT and YC BRT - when initially pushed, causes the related cabin zone lighting to come on with 100 % intensity. It also causes the integral lights in the related BRT, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession. 
R R R R R  (7) BC DIM1 and YC DIM1 - when initially pushed, causes the related cabin zone lighting to come on with 50 % intensity. It also causes the integral light in the related DIM 1, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession. 
R R R R R  (8) BC DIM2 and YC DIM2 - when initially pushed, causes the related cabin zone lighting to come on with 10 % intensity. It also causes the integral light in the related DIM 2, cabin WDO and cabin CLG membrane switch to come on. The lights may be switched off by pushing the membrane switch twice in succession.
 **ON A/C 301-399,
 (6) BRT - when initially pushed, causes the related cabin zone lighting to come on with 100 % intensity. It also causes the integral lights in the related pushbutton to come on.
 (7) DIM1 - when initially pushed, causes the related cabin zone lighting to come on with 50 % intensity. It also causes the integral light in the related DIM 1 pushbutton to come on.
 (8) DIM2 - when initially pushed, causes the related cabin zone lighting to come on with 10 % intensity. It also causes the integral light in the related DIM 2 pushbutton to come on. 

R 1EFF : 151-199, 201-299, 301-399, 1 33-21-00Page 36 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 (9) WDO - With the cabin lighting selected on, (at any intensity). On pushing this membrane switch, the window lights in each cabin zone and the integral light under the membrane switch foil go off. Pushing the membrane switch again will cause the lights to come on.
 (10) CLG - With the cabin lighting selected on, (at any intensity). On pushing this membrane switch, the ceiling lights in each cabin zone and the integral light under the membrane switch foil go off. Pushing the membrane switch again will cause the lights to come on.
 **ON A/C 051-099, 151-199, 201-210,
 C. AFT Attendant Panel (AAP)
 (1) Not Applicable
 (2) Not Applicable R **ON A/C 211-299,
 C. AFT Attendant Panel (AAP)
 NOTE : The AAP has no switches MAIN ON and MAIN OFF.

____
 (1) Not Applicable
 (2)
 Not Applicable
 **ON A/C 301-399,


 C. AFT Attendant Panel (AAP)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光1(55)