The reading lights are installed in the combi-panels. The combi-panels are installed in the Passenger Service Unit (PSU) channel above the passenger seats. The number of combi-panels on each side of the cabin must agree with the number of seat rows. Three reading lights are installed in each of the combi-panels 2040VUF, 2041vuf,2040VUG, and 2041vug. Two reading lights are installed in each of the combi-panels 2040VUK and 2041VUK. The middle reading light position of this combi-panels is blanked off.
**ON A/C 106-149, 211-299,
The reading lights are installed in the combi-panels. The combi-panels are installed in the Passenger Service Unit (PSU) channel above the passenger seats. The number of combi-panels on each side of the cabin must agree with the number of seat rows. Three reading lights are installed in each of the combi-panels 2040/2041VUF and 2040/2041VUG. Two reading lights are installed in each of the combi-panels 2040VUK and 2041VUK. The middle reading light position of this combi-panels is blanked off.
**ON A/C 151-199,
R R The reading lights are installed in the combi-panels. The combi-panels are installed in the Passenger Service Unit (PSU) channel above the passenger seats. The number of combi-panels on each side of the cabin must agree with the number of seat rows. Three reading lights are installed in each of the combi-panels 2040/2041VUG and 2040/2041VUN. Two reading lights are installed in the combi-panels 2040/2041VUK. The middle reading light position of this combi-panel is blanked off.
**ON A/C 301-399,
The reading lights are installed in the passenger service units (PSU). The PSU are installed in the PSU channel above the passenger seats. The number of PSU's on each side of the cabin must agree with the number of seat rows. Three reading lights are installed in each of the PSU 621RH and 623RH. One, two or three reading lights are installed in each of the PSU 622RH.
R **ON A/C 401-499,
R R R R R R R R R R The reading lights are installed in the combi-panels. The combi-panels are fitted in the Passenger Service Unit (PSU) channel above the passenger seats. The combi-panel fitted must agree with the number of seats in a row. The reading light configurations are listed below: - two reading lights are installed in the combi-panels 2040/2041VUJ and 2040/2041VUK with the middle position blanked off, - two reading lights are installed in the combi-panels 2040/2041VUE with the inboard position blanked off, - three reading lights are installed in the combi-panels 2040/2041VUF, 2040/2041VUG and 2040/2041VUR.
**ON A/C ALL
4. Power Supply____________
**ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
115VAC is supplied to the reading lights from the busbars 110XP and 210XP. This is controlled through the circuit breakers 1LW thru 6LW and the relays 7LW and 8LW. The power units 511RH thru 514RH change the 115VAC to 6VAC for the light operation. A fuse in each line gives protection for the transformer and the related Printed Circuit Board (PCB). A membrane switch POWER READ on the Forward Attendant Panel (FAP) 120RH controls the power supply for the reading lights.
**ON A/C 301-399,
115VAC is supplied to the reading lights from the busbars 110XP and 210XP. This is controlled through the circuit breakers 1LW thru 6LW and the relays 7LW and 8LW. The Stand Alone - Passenger Interface and Supply Adapter (StA-PISA) changes the 115VAC to 6VAC for the light operation. A fuse in each line gives protection for the transformer and the related Printed Circuit Board (PCB). The LIGHTS MAIN ON/OFF button on the light page of the Flight Attendant Panel (FAP) 120RH controls the power supply for the reading lights.
R **ON A/C 401-499,
R R R R R R R R 115VAC is supplied to the reading lights from the busbars 110XP and 210XP. This is controlled through the circuit breakers 1LW thru 6LW and the relays 7LW and 8LW. The power units 511RH and 512RH change the 115VAC to 6VAC for the light operation. A fuse in each line gives protection for the transformer and the related Printed Circuit Board (PCB). A membrane switch POWER READ on the Forward Attendant Panel (FAP) 120RH controls the power supply for the reading lights.