R **ON A/C 001-049, 051-060, 101-102, 201-201,
Subtask 33-25-00-710-050
A. Operational test of the Passenger Reading Light System
(1) Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the FWD Attendant Panel (FAP) On the FAP 120RH:
120RH:
- push the POWER READ membrane - the integral light of the POWER READ
switch. membrane switch comes on.
2. In the cabin: In the cabin:
- push all reading light - all the reading lights come on.
pushbutton-switches.
3. On the FAP 120RH: In the cabin:
- push to reset the POWER READ - all the reading lights go off.
membrane switch.
On the FAP 120RH:
- the integral light of the POWER READ
membrane switch goes off.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-in less than 10 s push the POWER READ membrane switch again.
-push to reset the POWER READ membrane switch.
-after more than 10 s push the POWER READ membrane switch again.
4. In the cabin:
-push all the reading light pushbutton-switches.
5. On the FAP 120RH:
-push the MAIN OFF membrane switch.
-the integral light of the POWER READmembrane switch comes on.
In the cabin:
-
all the reading lights come on.
-
all the reading lights go off.
On the FAP 120RH:
-
the integral light of the POWER READ membrane switch goes off.
-
the integral light of the POWER READmembrane switch comes on.
In the cabin:
-
all the reading lights come on.
In the cabin:
-
all the reading lights go off.
NOTE : The general illumination goes off if it is on.
____ On the FAP 120RH:
-the integral light of the POWER READ membrane switch goes off.
R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 33-25-00Page 503 1 1 May 01/05 1 1 1CES 1R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
Subtask 33-25-00-710-050-A
A. Operational test of the Passenger Reading Light System
(1) Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the FWD Attendant Panel (FAP) 120RH:
-push the POWER READ membrane switch.
2. In the cabin:
-push all reading light
pushbutton-switches.
3. On the FAP 120RH:
-push to reset the POWER READ membrane switch.
-in less than 2s push the POWER READ membrane switch again.
-push to reset the POWER READ membrane switch.
-after more than 2s push the POWER READ membrane switch again.
4. In the cabin: On the FAP 120RH:
-the integral light of the POWER READmembrane switch comes on.
In the cabin:
-
all the reading lights come on.
In the cabin:
-
all the reading lights go off.
On the FAP 120RH:
-
the integral light of the POWER READ membrane switch goes off.
-
the integral light of the POWER READmembrane switch comes on.
In the cabin:
-
all the reading lights come on.
-
all the reading lights go off.
On the FAP 120RH:
-
the integral light of the POWER READ membrane switch goes off.
-
the integral light of the POWER READmembrane switch comes on.
In the cabin:
R 1EFF : 061-099, 103-149, 151-199, 202-299, 1 33-25-00Page 504 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------- push all the reading light - all the reading lights come on. pushbutton-switches.