R General Illumination - Schematic Figure 001
R 1EFF : 1 1 1CES ALL 1 111 33-20-00 Page 2 Feb 01/00
Lavatory Lighting - Schematic (Example) Figure 002
1EFF : 1 1R 1CES ALL 1 11 1 33-20-00 Page 3 Aug 01/04
NOTE : The installation of the additional halogen light(s) is a customer
____
option.
C. Passenger Reading Lights (Ref. 33-25-00) The passenger reading lights are high intensity lights, which give additional illumination to the passengers. Each passenger controls his own reading light through a pushbutton. The cabin attendants control the power of the reading light system through a membrane switch (POWER READ) on the Forward Attendant Panel (FAP).
D. Lavatory Lighted Signs (Ref. Fig. 002) (Ref. 33-26-00) The lavatory lighted signs indicate if the lavatories are occupied or not. A microswitch in the lavatory door frame controls the power of the lavatory lighted signs.
E. Cabin Attendant Work-Lights (Ref. 33-27-00) The cabin attendant work-lights are high intensity lights, which give additional illumination to the attendants and their working areas. Each attendant controls his own work-light through a pushbutton. The cabin attendants control the power of the work-light system through a membrane switch (POWER ATTN) on the Forward Attendant Panel (FAP).
NOTE : The installation of the cabin attendant work-lights is a customer
____
option.
1EFF : ALL 1 33-20-00Page 4 1 1 Aug 01/04R 1 1 1CES 1
R CABIN - DEACTIVATION/REACTIVATION_________________________________
TASK 33-20-00-040-001
Deactivation of the Cabin NO SMOKING / FASTEN SEAT BELTS / RETURN TO SEAT (NS/FSB/RTS) Signs
1. Reason for the Job__________________
R R R Refer to the MMEL TASK: 33-20-02 b) Cabin - Cabin Signs (No Smoking/ Fasten Seat Belt/Return to Seat)
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notices
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
23-73-00-710-017 24-41-00-861-002 24-41-00-862-002 Operational Test of the Cabin SignsEnergize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Job Set-up__________
Subtask 33-20-00-861-051
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
4. Procedure
_________ Subtask 33-20-00-040-051
A. Deactivation of the Cabin NS/FSB/RTS Signs
(1)
Do the operational test of the cabin signs (Ref. TASK 23-73-00-710-017) and find the defective NS/FSB/RTS sign(s).
(2)
Find the passenger seats from which you cannot see the serviceable NS/FSB/RTS sign.
(3)
Put warning notices in position on these seats to tell the passengers not to use them.
NOTE : It must be possible to see a serviceable NS/FSB/RTS sign from
____
every passenger seat that is in use.