- busbar 206PP supplies the annunciator light test relay coils.
C. Switch 33LP
A switch with 3 positions: DIM, BRT, TEST is located on the overhead
control and indicating panel 25VU.
D. Fourteen Annunciator Light Test and Interface Boards
They are located in the avionics compartment in the annunciator light
test unit 70VU:
- 4 are associated with the annunciator lights supplied by the AC1
system.
They are identified by FINs 1LP to 4LP.
- seven are associated with the annunciator lights supplied by the
essential generation. They are identified by FINs 5LP to 11LP.
Three are associated with the annunciator lights supplied by the AC2
generation.
They are identified by FINs 18LP to 20LP.
Each board comprises:
- 2 relays supplied by busbar 206PP with 28VDC through circuit breaker
30LP located on the rear circuit breaker panel 122VU.
These 2 relays serve for the annunciator light tests when the switch
33LP is in the TEST position.
- 10 relays supplied by the various A/C systems with 28VDC. They supply
the annunciator light with 5VAC whereas the system data are supplied
with 28VDC.
E. Four-Stage Relays
They are located in the relay box 103VU. They all are identified with a
TEST placard. They serve for the test of the equipment annunciator lights
(high intensity) or of other annunciator lights (ON - OFF).
The busbar 206PP supplies 28VDC to the coil of these relays through the
circuit breaker 30LP located on the rear circuit breaker panel 122VU.
4. Operational/Control and Indicating__________________________________
R
R (Ref. Fig. 004)
R A. Annunciator Light Test for the External Power Panel 108VU
R The LIGHT TEST pushbutton switch 34LP on the panel 108VU serves to test
R the EXT PWR/NOT IN USE, EXT PWR/AVAIL, COCKPIT CALL, APU FIRE and ADIRU &
R AVNCS VENT indicator lights.
R The ADIRU & AVNCS VENT caution light is supplied from the 28VDC HOT BUS
R 704PP through the circuit breaker 6FP1 located on the circuit breaker
R panel 105VU.
R The EXT PWR/NOT IN USE, EXT PWR/AVAIL, COCKPIT CALL and APU FIRE
R indicator lights are supplied from the 28VDC BUSBAR 1IWPP through the
R circuit breaker 4XG located on the circuit breaker panel 122VU.
Annunciator Light Test and Dimming - Principle Diagram Figure 003 (SHEET 1)
1EFF : ALL 1 33-14-00Page 6 1 1 May 01/05R 1 1 1CES 1
Annunciator Light Test and Dimming - Principle Diagram Figure 003 (SHEET 2)
1EFF : ALL 1 33-14-00Page 7 1 1 May 01/05R 1 1 1CES 1
Control and Indicating-Panel 108VU
Figure 004
1EFF : ALL 1 33-14-00 Page 8
1 1 Feb 01/98
1 1
1CES 1
R If ground power is not available, only the ADIRU & AVNCS VENT caution 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光1(44)